Journal of Biomedical Physics & Engineering
Volume:5 Issue: 2, Mar-Apr 2015

  • تاریخ انتشار: 1394/03/02
  • تعداد عناوین: 7
|
  • S. J Hosseinialiabadi_S. M Hosseini Pooya_H. Afarideh_F. Mianji Page 49
    Background
    The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area.
    Objective
    A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry.
    Method
    Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval.
    Result
    The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method.
    Conclusion
    This system can be utilized in large scale environmental monitoring with a higher accuracy.
  • S. Sina_R. Faghihi_A. S Meigooni Page 53
    Background
    Most of the current brachytherapy treatment planning systems (TPS) use the TG-43U1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects.
    Objective
    The purpose of this study is developing a method for obtaining correction factors for heterogeneity for Cs-137 brachytherapy sources based on pre-calculated MC simulations and interpolation.
    Method
    To simulate the effect of phantom heterogeneity on dose distribution around Cs-137 sources, spherical water phantoms were simulated in which there were spherical shells of bone with different thicknesses (0.2cm to 1.8cm with 0.1cm increment) at different distances (from 0.1cm to 10cm, with 0.5cm increment) from the source center. The spherical shells with 0.1cm thickness at different distances from 0.1cm to 10cm were used as tally cells. The doses at these cells were obtained by tally types F6, *F8, and *F4.The results indicate that the percentage differences between the doses in heterogeneity sections with the dose at the same positions inside the homogeneous water phantom vary when the distance of bone section from the source center increases, because of decreasing the average energy of photons reaching the bone layer. Finally, the results of Monte Carlo simulations were used as the input data of MATLAB software, and the percentage dose difference for each new configuration (i.e. different thickness of inhomogenity at different distances from the source) was estimated using the 2D interpolation of MATLAB.
    Results
    According to the results, the algorithm used in this study, is capable of dose estimation with high accuracy.
    Conclusion
    The developed method using the results of Monte Carlo simulations and the dose interpolation can be used in treatment planning systems for heterogeneity corrections.
  • S. M J. Mortazavi_S. Rahimi_M. A Mosleh_Shirazi_M. Arjomandi_A. Soleimani_O. Koohi Hossein_Abadi_M. Haghani_M. Alavi Page 59
    Introduction
    Oral intake of vitamins which present antioxidant characteristics can protect living organisms against oxidative damage caused by exposure to ionizing radiation. It was previously reported that administration of high levels of vitamin C can lead to increased DNA damage through production of hydroxyl radicals from hydrogen peroxide by the Fenton reaction. However, our early experiments did not confirm this hypothesis. The main goal of this study was to determine if high doses of Vit C can show life-saving radioprotective effects.
    Materials And Methods
    Phase I: Seventy two male Balb/c mice weighing 20-25g were randomly divided into six groups of 12 animals each. Group I; Vit E for five days, Groups II and III; Vit C and Vit A. Group 4; all three vitamins. Group V; an over-the-counter multivitamin. Group VI; none of the above. Phase II: 120 male BALB/c mice weighing 20-25g were randomly divided into 12 groups of 10 each. Group I; Vit A for five days. Groups II-IV; Vit C 200 mg/kg, 400 mg/kg, 800 mg/kg, respectively. Group V-VII; Vit E at daily doses of 200 iu/kg, 400 iu/kg, 800 iu/kg, respectively. Group VIII and IX; all three vitamins at low and high doses, respectively. Group X; an over-the-counter multivitamin. Group XI; controls group and Group XII; received pure olive oil. All animals (Phases I and II) were exposed to a lethal dose of gamma rays and the survival rates of the animals were monitored and recorded continuously for 16 days after exposure.
    Results
    Phase I: 14 days after irradiation the survival rate for control group was 33.33%, while the survival rates for the 1st to 5th groups were 45.45%, 81.81%, 50%, 57.14%, and 9.09%, respectively. Phase II: The survival rates in the control group and the group that only received pure olive oil, were 50% and 60%, respectively. Survival rate in the animals received Vit C at daily doses of 200 mg/kg, 400 mg/kg, 800 mg/kg, were 90%, 90% and 90%, respectively. Log rank (Mantel-Cox) test showed statistically significant differences between the survival rates in control irradiated mice (no vitamins) and mice received Vit C at daily doses of 200 mg/kg (P=0.042), 400 mg/kg (P=0.042) and 800 mg/kg (P=0.042).
    Conclusion
    Altogether, findings of this study showed that even high doses of Vit C can show life-saving radioprotective effects. The significant radioprotective effect of Vit C at doses used in this study, opens new horizons in developing non-toxic, cost effective, easily available radioprotectors in life-threatening situations such as exposure to lethal doses of ionizing radiation. The radioprotective effect of Vit A and Vit E seem to be less efficient compared to that of Vit C.
  • M. Kazempoor, M. Saeedimoghadam, F. Shekoohi Shooli, N. Shokrpoor Page 67
    Background
    In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range.
    Objective
    Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for alternative materials to be used instead of lead apron because of some problems derived from lead-content of aprons. Because of its lead-content, these radiation protection garments are so heavy and uncomfortable for the staff to wear, particularly in long-time uses. In addition, lead is a toxic element and its disposal is associated with environmental and human-health hazards.
    Method
    In this study, several new combinations of lead free materials ((W-Si), (W-Sn-Ba-EPVC), (W-Sn-Cd-EPVC)) have been investigated in the energy range of diagnostic radiology in two geometries: narrow and broad beam. Geometries of the radiation attenuation characteristics of these materials was assessed in 40, 60, 90 and 120 kVp and the results compared with those of some lead-containing materials ((Pb-Si), (Pb-EPVC)).
    Results
    lead shields still provide better protection in low energies (below 40 kVp). Combination of W-Sn-Cd-EPVC has shown the best radiation attenuation features in 60 and 90 kVp and the composition of (W-Sn-Ba-EPVC) represents the best attenuation in 120 kVp, even better than previously mentioned lead- containing composites.
    Conclusion
    Lead free shields are completely effective for protection against X-ray energies in the range of 60 to 120 kVp.
  • A. R Farajollahi_F. Bouzarjomehri_M. Kiani Page 77
    Introduction
    In radiation therapy centers across Iran, protection of normal tissues is usually accomplished by either Cerrobend or lead block shielding. In this study, the influence of these two shielding methods on central axis dose distribution of photon beam a Cobalt unit was investigated in clinical conditions.
    Materials And Methods
    All measurements were performed for 60Co γ-ray beams and the Cerrobend blocks were fabricated by commercial Cerrobend materials. Standard lead block shields belonged to Cobalt unit. Data was collected through a calibrated ionization chamber, relative dosimetry systems and a TLD dosimetery.
    Results
    Results of the percent depth dose (PDD) measurements at depths of 0.5, 1, 5, 10, 15 and 20 cm for 23 different field sizes of patients with head and neck cancer showed no significant differences between lead and Cerrobend shielding methods. Measurement results of absolute dosimetry in depths of 1.5, 3, 5, 7, 10 and 12 cm also showed no significant differences between these two shielding methods. The same results were obtained by TLD dosimetry on patient skin.
    Conclusion
    Use of melt shielding methods is a very easy and fast shield-making technique with no differences in PDD, absolute and skin dose between lead and Cerrobend block shielding methods.
  • D. Arefan, A. Talebpour, N. Ahmadinejhad, A. Kamali Asl Page 83
    Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study ultra-fast image reconstruction technique for Tomosynthesis Mammography systems using Graphics Processing Unit (GPU). At first, projections of Tomosynthesis mammography have been simulated. In order to produce Tomosynthesis projections, it has been designed a 3D breast phantom from empirical data. It is based on MRI data in its natural form. Then, projections have been created from 3D breast phantom. The image reconstruction algorithm based on FBP was programmed with C++ language in two methods using central processing unit (CPU) card and the Graphics Processing Unit (GPU). It calculated the time of image reconstruction in two kinds of programming (using CPU and GPU).