Journal of Biomedical Physics & Engineering
Volume:6 Issue: 3, May-Jun 2016

  • تاریخ انتشار: 1395/07/03
  • تعداد عناوین: 10
|
  • J. Beik_A. R Mehdizadeh_A. Shakeri_Zadeh Page 123
  • T. R Verma_N. K Painuly_S. P Mishra_M. Shajahan_N. Singh_M. L B. Bhatt_N. Jamal_M. C Pant Page 127
    Background
    Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.
    Objective
    In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy planning.
    Materials And Methods
    Treatment plans for ten lung cancer patients previously planned on Monte Carlo algorithm were re-planned using same treatment planning indices (gantry angel, rank, power etc.) in other four algorithms.
    Results
    The values of radiotherapy planning parameters such as Mean dose, volume of 95% isodose line, Conformity Index, Homogeneity Index for target, Maximum dose, Mean dose; %Volume receiving 20Gy or more by contralateral lung; % volume receiving 30 Gy or more; % volume receiving 25 Gy or more, Mean dose received by heart; %volume receiving 35Gy or more; %volume receiving 50Gy or more, Mean dose to Easophagous; % Volume receiving 45Gy or more, Maximum dose received by Spinal cord and Total monitor unit, Volume of 50 % isodose lines were recorded for all ten patients. Performance of different algorithms was also evaluated statistically.
    Conclusion
    MC and PB algorithms found better as for tumor coverage, dose distribution homogeneity in Planning Target Volume and minimal dose to organ at risks are concerned. Superposition algorithms found to be better than convolution and fast superposition. In the case of tumors located centrally, it is recommended to use Monte Carlo algorithms for the optimal use of radiotherapy.
    Keywords: Monte Carlo, Lung IMRT, Algorithms, Pencil Beam, Superposition, Dose to OARs
  • M. Alavi_S. Taeb_M. A Okhovat_M. Atefi_F. Negahdari Page 139
    Background
    Hormesis is defined as the bio-positive response of something which is bio-negative in high doses. In the present study, the effect of radiation hormesis was evaluated on the survival rate of immunosuppressed BALB/c mice by Cyclosporine A.
    Materials And Methods
    We used 75 consanguine, male, BALB/c mice in this experiment. The first group received Technetium-99m (3700Bq) and the second group was placed on a sample radioactive soil of Ramsar region (800Bq) for 20 days. The third group was exposed to X-rays (3600Bq) and the fourth group was placed on the radioactive soil and then injected Technetium-99m. The last group was the sham irradiated control group. Finally, 30mg Cyclosporine A as the immunosuppressive agent was orally administered to all mice 48 hours after receiving X-rays and Technetium-99m. The mean survival rate of mice in each group was estimated during time.
    Results
    A log rank test was run to determine if there were differences in the survival distribution for different groups and related treatments. According to the results, the survival rate of all pre-irradiated groups was more than the sham irradiated control group (p
    Conclusions
    This study confirmed the presence of hormetic models and the enhancement of survival rate in immunosuppressed BALB/c mice as a consequence of low-dose irradiation. It is also revealed the positive synergetic radioadaptive response on survival rate of immunosuppressed animals.
    Keywords: Radiation Hormesis, Survival Rate, BALB, c mice, Cyclosporine A, Radioadaptive Response
  • B. Farhood_M. T Bahreyni Toossi_H. Vosoughi_S. Khademi_C. Knaup Page 147
    Background
    Breast cancer is the most frequently diagnosed cancer and the leading global cause of cancer death among women worldwide. Radiotherapy plays a significant role in treatment of breast cancer and reduces locoregional recurrence and eventually improves survival. The treatment fields applied for breast cancer treatment include: tangential, axillary, supraclavicular and internal mammary fields.
    Objective
    In the present study, due to the presence of sensitive organ such as thyroid inside the supraclavicular field, thyroid dose and its effective factors were investigated.
    Materials And Methods
    Thyroid dose of 31 female patients of breast cancer with involved supraclavicular lymph nodes which had undergone radiotherapy were measured. For each patient, three TLD-100 chips were placed on their thyroid gland surface, and thyroid doses of patients were measured. The variables of the study include shield shape, the time of patient’s setup, the technologists’ experience and qualification. Finally, the results were analyzed by ANOVA test using SPSS 11.5 software.
    Results
    The average age of the patients was 46±10 years. The average of thyroid dose of the patients was 140±45 mGy (ranged 288.2 and 80.8) in single fraction. There was a significant relationship between the thyroid dose and shield shape. There was also a significant relationship between the thyroid dose and the patient’s setup time.
    Conclusion
    Beside organ at risk such as thyroid which is in the supraclavicular field, thyroid dose possibility should be reduced. For solving this problem, an appropriate shield shape, the appropriate time of the patient’s setup, etc. could be considered.
    Keywords: Thyroid Dose, Breast Cancer, Radiotherapy, Supraclavicular Field, TLD
  • F. Shekoohi_Shooli_S. M J. Mortazavi_M. B Shojaei_Fard_S. Nematollahi_M. Tayebi Page 157
    Background
    The use of devices emitted microwave radiation such as mobile phones, wireless fidelity (Wi-Fi) routers, etc. is increased rapidly. It has caused a great concern; the researchers should identify its effects on people’s health. We evaluated the protective role of Vitamin C on the metabolic and enzymatic activities of the liver after exposure to Wi-Fi routers.
    Material and
    Methods
    70 male Wistar rats weighing 200-250 g were randomly divided into 7 groups (10 rats in each group).The first stage one –day test: Group A (received vitamin C 250 mg/kg/day orally together with 8- hour/day Wi-Fi exposure).Group B (exposed to Wi-Fi radiation). Group C (received vitamin C). Group D or Control (was neither exposed to radiation of Wi-Fi modem nor did receive vitamin C). The second phase of experiment had done for five consecutive days. It involved Group E (received vitamin C), Group F (exposed to Wi-Fi radiation), Group G (received vitamin C together with Wi-Fi radiation). The distance between animals’ restrainers was 20 cm away from the router antenna. Finally, blood samples were collected and assayed the level of hepatic enzymes including alkaline phosphatase(ALP), alanine amino transferase(ALT) aspartate amino transferase (ASL), gamma glutamyl transferase (GGT) and the concentration of Blood Glucose, Cholesterol , Triglyceride(TG),High density lipoprotein (HDL)and low density lipoprotein (LDL).
    Results
    Data obtained from the One day test showed an increase in concentration of blood glucose, decrease in Triglyceride level and GGT factor (P
    Conclusion
    WiFi exposure may exert alternations on the metabolic parameters and hepatic enzymes activities through stress oxidative and increasing of free radicals, but the use of vitamin C protects them from changing induced. Also taking optimum dose of vitamin C is essential for radioprotective effect and maintaining optimum health.
    Keywords: Wi, Fi modem, Vitamin C, Hepatic enzyme activities
  • A. Rezaeyan_R. Fardid_G. H Haddadi_M. A Takhshid_M. Hosseinzadeh_M. Najafi_A. Salajegheh Page 165
    Background
    Oxidative stress plays an important role in the pathogenesis and progression of γ-irradiation-induced cellular damage, Lung is a radiosensitive organ and its damage is a dose-limiting factor in radiotherapy. The administration of dietary antioxidants has been suggested to protect against the succeeding tissue damage. The present study aimed to evaluate the radioprotective efficacy of Hesperidin (HES) against γ-irradiation-induced tissue damage in the lung of male rats.
    Materials And Methods
    Thirty two rats were divided into four groups. Rats in Group 1 received PBS and underwent sham irradiation. Rats in Group 2 received HES and underwent sham irradiation. Rats in Group 3 received PBS and underwent γ-irradiation. Rats in Group 4 received HES and underwent γ-irradiation. These rats were exposed to γ-radiation 18 Gy using a single fraction cobalt-60 unit, and were administered HES (100 mg/kg/d, b.w, orally) for 7 days prior to irradiation. Rats in each group were sacrificed 24 hours after radiotherapy (RT) for the determination of superoxide dismutase (SOD), glutathione (GSH), malondialdehyde (MDA) and histopathological evaluations.
    Results
    Compared to group 1, the level of SOD and GSH significantly decreased and MDA level significantly increased in group 3 at 24 h following irradiation, (p=0.001, p0.0125).
    Conclusion
    Oral administration of HES was found to offer protection against γ-irradiation- induced pulmonary damage and oxidative stress in rats, probably by exerting a protective effect against inflammatory disorders via its free radical scavenging and membrane stabilizing ability.
    Keywords: Hesperidin, Radioprotector, Oxidative Stress, Inflammation
  • A. Tavakoli Golpaygani_M. M Movahedi_M. Reza Page 175
    Introduction
    Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient’s safety and management of the risks associated with the use of high and low frequency electrical currents on human body.
    Material and
    Methods
    The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public) was evaluated in one of the provinces of Iran according to international and national standards.
    Results
    The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low.
    Conclusion
    Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.
    Keywords: Meterology, Electrosurgical Equipmen, High Frequency, Patient Safety, Medical Electrical Equipment
  • Z. Abed_J. Beik_S. Khoee_S. Khoei_A. Shakeri_Zadeh_M. B Shiran Page 183
    Background
    Drug nano-carriers are one of the most important tools for targeted cancer therapy so that undesired side effects of chemotherapy drugs are minimized. In this area, the use of ultrasound can be helpful in controlling drug release from nanoparticles to achieve higher treatment efficiency.
    Objective
    Here, we studies the effects of ultrasound irradiation on the release profile of 5-fluorouracil (5-Fu) loaded magnetic poly lactic co-glycolic acid (PLGA) nanocapsules.
    Methods
    5-Fu loaded magnetic PLGA nanocapsules were synthesized by multiple emulsification method. Particle size was measured by dynamic light scattering (DLS) and transmission electron microscope (TEM). The pattern of drug release was assessed with and without 3 MHz ultrasound waves at intensities of 0.3, 0.5 and 1 w/cm2 for exposure time of 5 and 10 min in phosphate-buffered saline (PBS).
    Results
    The size of nanoparticles was about 70 nm. Electron microscope images revealed the spherical shape of nanoparticles. The results demonstrated that the intensity and exposure time of ultrasound irradiation have significant effects on the profile of drug release from nanoparticles.
    Conclusion
    It may be concluded that the application of ultrasound to control the release profile of drug loaded nanocapsules would be a promising method to develop a controlled drug delivery strategy in cancer therapy.
    Keywords: Nanoparticle, Ultrasound, Cancer, PLGA, 5, Fu
  • M. Mehrpour_A. Shakeri_Zadeh_P. Basir_B. Jamei_H. Ghaheri_M. B Shiran Page 195
    Background
    Low intensity ultrasound (US) has some well-known bio-effects which are of great importance to be considered.
    Objectives
    We conducted the present study to investigate the effects of low intensity continuous ultrasound on blood cells count in rat.
    Methods
    Rats were anesthetized and blood samples were collected before US exposure. Then, they were exposed to US with nominal intensity of 0.2 W/cm2 at frequency of 3 MHz for a period of 10 minutes and this protocol was repeated for 7 days. Twenty four hours after the last US exposure, secondary blood samples were collected and the changes in blood parameters were evaluated.
    Results
    Analysis revealed that platelets, hematocrit (HCT) and hemoglobin (HGB) were significantly different between experimental and sham groups but no difference between sham and control groups was observed. The results show that HCT and HGB of exposed rats were significantly reduced.
    Conclusion
    This study shows that low intensity US may lead to side effects for hematological parameters such as reduction in the levels of HGB and HCT.
    Keywords: Low Intensity Ultrasound, Continuous Wave, Blood Cells, Hematological Test, Biological Effects
  • A. Shafe_S. M J. Mortazavi_A. Joharnia_Gh H. Safaeyan Page 201
    Accidental or intentional release of radioactive materials into the living or working environment may cause radioactive contamination. In nuclear medicine departments, radioactive contamination is usually due to radionuclides which emit high energy gamma photons and particles. These radionuclides have a broad range of energies and penetration capabilities. Rapid detection of radioactive contamination is very important for efficient removing of the contamination without spreading the radionuclides. A quick scan of the contaminated area helps health physicists locate the contaminated area and assess the level of activity. Studies performed in IR Iran shows that in some nuclear medicine departments, areas with relatively high levels of activity can be found. The highest contamination level was detected in corridors which are usually used by patients. To monitor radioactive contamination in nuclear medicine departments, RadRob15, a contamination detecting robot was developed in the Ionizing and Non-ionizing Radiation Protection Research Center (INIRPRC). The motor vehicle scanner and the gas radiation detector are the main components of this robot. The detection limit of this robot has enabled it to detect low levels of radioactive contamination. Our preliminary tests show that RadRob15 can be easily used in nuclear medicine departments as a device for quick surveys which identifies the presence or absence of radioactive contamination.
    Keywords: Robot, Radioactivity, Contamination, Radiation Detection