Abstract:
Background
In intertrochanteric fractures, dynamic hip screw (DHS) is the most frequently used tool, but several studies did not give good results for this device in reverse-oblique and transverse fractures. Current study aimed to compare fixation results of reverse-oblique intertrochanteric and short-segment subtrochanteric fractures using dynamic condylar screw (DCS) and DHS in patients referred to Alzahra and Kashani Hospitals in Isfahan, Iran.
Methods
In a cross-sectional study, medical files of the patients referred to emergency units of the two hospitals who were diagnosed with intertrochanteric or subtrochanteric fractures and underwent DHS or DCS surgery more than 6 months before were assessed; they were invited for follow-up visit and examination. Written consent forms were taken from all the patients upon their entry; and they were examined in terms of complications including nonunion and failure of device and level of fracture improvement. These cases were evaluated by simple radiography, too. Results obtained from examination of patients in addition to demographic information were recorded in the data collection form for each patient.
Findings: Perfect union was observed in 14 (of 25) patients in DHS group and 21 (of 25) patients in DCS group (56% vs. 84%) six months after the surgery. Bone union was significantly better in DCS group (P = 0.031). In addition, six months after the surgery, the devices used in 14 people in DHS group and 24 people in DCS group were fixed and the difference between the two groups was significant (P = 0.001). 14 and 24 patients had total recovery in DHS and DCS groups, respectively (20% vs. 44%) with a significant difference (P = 0.020).
Conclusion
Considering obtained results, it can be concluded that using DCS is recommended over DHS due to severity of pain, bone union and fixation of the device.
Language:
Persian
Published:
Journal Of Isfahan Medical School, Volume:34 Issue: 395, 2016
Pages:
952 to 957
magiran.com/p1609154  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!