The effect of type and mode of light curing units on degree of conversion of Bulk Fill composites

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Introduction

 Adequate polymerization is a critical factor in obtaining optimal physical and mechanical properties and a satisfying clinical performance of composite restorations. The aim of this study was to evaluate the effect of type and mode of light curing unites on degree of conversion (DC) of Bulk Fill composites (Xtra-fill andTetric N-Ceram Bulk Fill) compared with a conventional composite (Tetric N-Ceram).

Materials and Methods

 This in-vitro experimental study was conducted in Kerman and Tehran School of Dentistry in 2019. Number of 15 uncured composites and 45 composite discs were fabricated using the Teflon molds with a 4 mm thick and 10 mm diameter and light cured from the top using LED ramp, LED and QTH curing units for 20 seconds. Bulk Fill composites (Xtra-fill andTetric N-Ceram Bulk Fill) were placed with a 4mm_thick increment and conventional composite (Tetric N-Ceram) was placed incrementally (with 2 mm thickness in each layer). The degree of conversion of top and bottom surfaces of composites were measured using the Fourier Transform Infrared Spectroscopy (FTIR). The results were analyzed with Two-way ANOVA and Tukey̛ s test. p value < 0.05 was set at the level of significant.

Results

 In all samples, the DC value of top surfaces was significantly higher than the 4mm depth (p value < 0.05). Overally, there were no significant differences between the DC value of tested composites(p value > 0.05), But LED light in ramp mode showed significantly better results compared to LED and QTH light sources(p value < 0.05). The type and mode of light cure units had no influence on DC of bulk fill composites (p value > 0.05), but the DC of conventional composite with QTH and LED ramp was significantly higher than LED (p value < 0.05).

Conclusion

The results of this study showed that the DC value of bulk fill composites were not significantly affected by the type and mode of light cure units, and all investigated bulk fill composites obtained clinically acceptable degree of conversion at 4 mm depth.

Language:
Persian
Published:
Journal of Isfahan Dental School, Volume:18 Issue: 2, 2022
Pages:
145 to 152
magiran.com/p2464180  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!