Introduction
Scaling and root planing is one of the most commonly used procedures during periodontal treatments. Removal of calculus using conventional hand instruments is incomplete and rather time consuming. To find more efficient and less difficult instrumentation method, investigators have proposed lasers as an alternative or adjunct to hand instruments for scaling and root planing. The aim of the present study was to compare the effectiveness of three methods of hand instruments, ultrasonic and Er:YAG laser for scaling & root planing of root surfaces with SEM method.Methods and materials: This was an experimental study and samples included 15 extracted premolars collected from patients with periodontal problem. The teeth were sectioned in two parts vertically. Therefore 30 samples were randomly divided in two groups. In the first group each surface of root from CEJ was divided in two parts. One part was scaled with manual curret and another by Er:YAG laser and third group was cleaned by ultrasonic methods. Another surface was considered as control group. The surface changes were evaluated by SEM in magnification of 50, 400 and 750 by 5 Examiners. Data was analyzed by SPSS program.
Results
The findings show that surface roughness is more in control group comparing with three other groups. Besides roughness from the most to the least belong to: ultrasonic group, laser group & manual scaling group. Kruscal-wallis test & Mann-Whitney test showed that there was a significant difference in the amount of surface roughness between manual group & laser group and also between control group & other groups and between manual and ultrasonic group. But there was no significant difference between rate of surface roughness in laser and ultrasounic group.
Conclusion
The efficacy of Er:YAG laser for scaling & root planing is not more than manual and ultrasonic instruments the amount of surface roughness created by Er:YAG is more than manual scaling but the difference is not significant comparing to ultrasonic scaling.
Language:
Persian
Published:
Journal of Isfahan Dental School, Volume:2 Issue: 1, 2006
Pages:
15 to 20
magiran.com/p468922  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!