Evaluation of polymerization of an experimental bonding resin cured with light emitting diodes using Differential Scanning Calorimetry

Message:
Abstract:
Background And Aim
Extent of polymerization (Ep) is the rate at which methacrylate C=C bonds are converted to aliphatic C-C bonds. The higher the Ep value, the better the polymerization of the polymer. If the polymer dose not polymerize sufficiently, it could have destructive effects e.g. releasing monomer, initiator, free radical or insufficient polymerization of hybrid layer. Therefore, measuring the Ep value is very important. Light-emitting diodes (LEDs) are becoming increasingly popular in dental practice as they have a long life expectancy. LEDs do not generate infrared wavelength, and have a constant light output. Therefore, comparison of LED and Quartz tungsten halogen (QTH) from the point of Ep is important. Differential Scanning Calorimetry (DSC) is a proper tool for determining the Ep value, monitoring the process of reaction and reaction kinetics. The aim of this study was to measure the Ep value of a dental bonding containing camphorquinone/amine photoinitiator which were cured by LED and QTH using DSC.
Materials And Methods
In this experimental study, 2.5 mg of bonding material were placed in DSC aluminum pans. Two different light cures, LED & QTH (Coltene Company Coltolux ®75 LED Curing Light), were used in this study. The light guide was positioned at a distance of 9mm from the base of the sample chamber. Each sample was photopolymerized for 30 seconds, and the DSC curves were obtained after 100 seconds from initiation of photopolimerization of each sample, at both 23oC and 37oC. The heat of photopolymerization (DH) was calculated from the area under the peak of the differential temperature curve. Five samples were used for each condition. The data was analyzed by two-way ANOVA.
Results
There was highly significant difference between two temperatures in the experimental bonding (pvalue<0.001). Representative DSC curves showed the same kinetic behavior for LED and QTH.
Conclusion
The results revealed that the Ep generated by high power density QTH was the same as that of produced by second generation of LED.
Language:
Persian
Published:
Journal of Dental Medicine, Volume:22 Issue: 1, 2009
Page:
41
magiran.com/p645997  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!