Effect of Platform Switching on Crestal Bone Stress Distribution around 3i Implants: a Finite Element Analysis

Message:
Abstract:
Background and Aim

Over the last few years, concept of platform switching has gained popularity for reducing degree of crestal bone resorption. Many researchers believe that, this theory can be used for improving stress distribution in implant-bone interface. The purpose of this three dimensional Finite Element Analysis (FEA) was to study and compare stress distribution in implant-bone interface and implant-abutment interface of 3i implants (Biomet 3i, USA) in mandibular molar area.

Materials and Methods

For this FEA, computed tomography (CT) images of an adult human mandible was used to make the three-dimensional model of posterior edentulous mandible. The implant systems which used was the 3i system consisted of 3i fixtures: 4 and 5 mm in diameter and 11.5 mm in length, and 3i Certain abutment 4.1 and 5mm (Biomet 3i, USA). This implant systems were assembled on the mandible model in 3 different designs: a platform-switched configuration; MODEL 4: 4-mm 3i fixture, 4.1-mm abutment; MODEL 5: 5-mm 3i fixture, 5-mm abutment; MODEL 6: 5-mm 3i fixture, 4.1-mm abutment, a platform-switched configuration. A linear static analysis was performed on the prepared 3D solid models with two different oblique load of 100 and 250 N in the lingobuccal direction with 15 degrees of inclination on the center of the abutment.

Results

Regardless of the implant system used, maximum Von Mises stresses in cortical bone around implants were lower in platform switched models compared to matching diameter implant-abutment. This effect was not related to the usage of larger implant diameters in these models. However, Von Mises stresses in implant-abutment interface were the lowest in models with larger implant diameter.

Conclusion

The platform switching technique reduces the stress concentration in the area of crestal bone-implant interface and shifted it to the area of implant-abutment interface. In the present study, this stress reduction was not related to increasing Implant diameter.

Language:
Persian
Published:
Journal of Dental School, Volume:29 Issue: 4, 2011
Page:
241
magiran.com/p937734  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!