BACTERIAL BIOAEROSOLS IN THE OPERATING ROOMS: A CASE STUDY IN TEHRAN SHARIATI HOSPITAL

Abstract:
Introduction
Maintenance of adequate hospital indoor air quality (HIAQ) in operating rooms (ORs) is critical to the Surgical Site Infection (SSI) in hospitalized patients. This study assessed the concentration of bacterial bioaerosols in various ORs in a hospital.
Materials And Methods
The concentration of bacterial bioaerosols was measured in the 8 ORs and 2 nurse stations. Active sampling method was used to monitor bacterial bioaerosols.
Results
The mean concentrations of the total bacteria were 211-386 and 208-443 CFU/ m3 in the first and second floor, respectively. Gram-positive bacteria (e.g., Micrococcus spp., Staphylococcus spp. and streptococcus spp.) were frequently observed in the assessed ORs and nurse stations.
Conclusions
Bacterial bioaerosol monitoring is a useful tool for evaluation of the bio-contamination of ORs in order to improve indoor air quality of them.
Language:
English
Published:
Journal of Air Pollution and Health, Volume:1 Issue: 3, Summer 2016
Pages:
215 to 218
magiran.com/p1580281  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!