Background
Quantitative shear wave elastography (SWE) has been developed and utilized to aid in the differentiation between benign and malignant breast lesions based on their stiffness..
Objectives
The purpose of this study was to evaluate the clinical effects of the additional use of SWE to conventional ultrasound (US) according to the maximum (Emax) and mean (Emean) elasticitiy values..
Patients and
Methods
A total 115 patients with 133 lesions were assessed using conventional US and SWE. All patients underwent US-guided core needle biopsy or surgery, and the pathological results were used as reference standards. We compared the diagnostic values including sensitivities, specificities, positive predictive values (PPVs) and negative predictive values (NPVs) and accuracies of conventional US and SWE according to the Emax and Emean values. Next, we obtained the optimal Emax and Emean cutoff values for SWE. Using these cutoff values, we analyzed the clinical effects of the additional use of SWE to conventional US based on the corrected results..
Results
Of the 133 breast lesions, 32 were malignant and 101 were benign. In the differentiation of benign and malignant lesions, conventional US resulted in sensitivity of 100 %, specificity of 43.0 %, PPV of 57.1 %, NPV of 36.7 %, and accuracy of 100 %. Regarding SWE, the sensitivity, specificity, PPV, NPV, and accuracy values based on Emax were 84.4 %, 89.1 %, 71.1 %, 94.7 %, and 88.0 %, respectively, and the corresponding values based on Emean were 84.8 %, 93.0 %, 91.0 %, 80.0 %, and 94.9 %, respectively. The optimal Emax and Emean cutoff values were 81.3 and 60.7 kPa, respectively. However, there was no significant difference between Emax and Emean. The corrected results related to the additional use of SWE to conventional US indicated 97.0 % sensitivity, 93.0 % specificity, 82.1 % PPV, 98.9 % NPV, and 94.0 % accuracy (P
Conclusion
The additional use of SWE to conventional US resulted in marked improvements in specificity, PPV, and accuracy and slight diminutions in sensitivity and NPV for the differentiation benign and malignant breast lesions. Both Emax and Emean were effective diagnostic parameters, and there was no significant difference between these two parameters..
Language:
English
Published:
Iranian Journal of Radiology, Volume:14 Issue: 1, Jan 2017
Page:
24
magiran.com/p1656230  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!