Comparison of the Diagnostic Performance of Breast Ultrasound and CAD Using BI-RADS Descriptors and Quantitative Variables

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
 
Background
Computer-aided diagnosis (CAD) as an adjunct to breast ultrasonography (US) has been extensively developed using different breast imaging techniques to help improve radiologists’ diagnostic performance, particularly in distinguishing malignant from benign breast lesions. Additionally, quantitative variables can be obtained using CAD.
Objectives
The aim of this study was to evaluate the usefulness of CAD as an adjunct to breast US by exploring the diagnostic performance of US and CAD using the breast imaging reporting and data system (BI-RADS) descriptors and quantitative variables. Patients and
Methods
Between October 2015 and December 2016, we performed breast US with CAD (S-Detect) for screening or diagnostic purposes. We assessed the diagnostic performance according to the BI-RADS descriptors, quantitative variables (width, height, height/width (H/W) ratio, area, and depth), and combined results. We analyzed the agreement in the descriptors between US and CAD.
Results
Four hundred thirty-two women with 521 breast lesions were enrolled. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of US vs. CAD were 0.82 vs. 0.78, 95% vs. 78%, and 69% vs. 78%, respectively. When CAD was combined with breast US, the specificity was significantly improved from 69% to 72% (P < 0.05). Among all descriptors and quantitative variables, the height and H/W ratio exhibited the greatest AUC (0.76 and 0.75), and the H/W ratio had the highest sensitivity (90%). According to the concordance analysis, the orientation exhibited the greatest agreement (k = 0.57).
Conclusion
Using CAD, we could accurately determine the BI-RADS descriptors, quantitative variables and improve the specificity. Additionally, the orientation and H/W ratio are consistent key factors for both US and CAD.
Language:
English
Published:
Iranian Journal of Radiology, Volume:16 Issue: 1, Jan 2019
Page:
13
magiran.com/p1924089  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!