Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma

Message:
Abstract:
Background
Recently, biuret derivatives have been reported as showing moderate to good cytotoxic effect against certain cancer cell lines. In this study, a high-performance liquid chromatography method was developed for determination of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret (PEQB) in rat plasma to use in future studies on this compound and related derivatives..
Objectives
In this study, we describe a simple and sensitive high-performance liquid chromatography method with UV detection for determination of 1-(2-phenylethyl)-6-(quinaldin-4-yl) biuret (PEQB) in rat plasma..
Materials And Methods
Separations were performed on a Nucleosil-100 CN HPLC column (125 × 4.0 mm) (5 µm), using a mixture of acetonitrile: methanol: potassium dihydrogen phosphate buffer (0.05 M, pH 3.5) (10:10:80) as mobile phase delivered at a flow rate of 1 mL/minute. Detection of PEQB and internal standard (1-([[3-(1,3-benzothiazol-2-ylsulfanyl)propyl]carbamoyl]amino)-N-phenylformamide) was performed at 235 nm and ambient temperature. Plasma samples (200 µL) were prepared by addition of 40 µL internal standard (100 µg/mL), and 400 µL acetonitrile. After vortex mixing and centrifugation at 10000 g, 50 µL of the clear supernatant was directly injected onto the chromatography column. Calibration curves were constructed by fitting the peak area ratio of the biuret to internal standard against concentration of biuret to a power model using generalized least squares nonlinear regression method..
Results
Under the above chromatography condition, biuret compound (PEQB) and the internal standard were detected at 4.5 and 13.5 minutes, respectively. Limit of quantitation of the PEQB was 0.1 µg/mL. Accuracy of the method over the concentration range of 0.1-100 µg/mL was between 88-109%. Inter- and intraday precisions were 4-19% and 6-8%, respectively. A good relationship in the form of a power model was found for two separate concentration ranges of 0.1-1 and 2.5-100 µg/mL (R 2> 0.99)..
Conclusions
The presented simple HPLC method is sufficiently accurate, precise and sensitive for the quantitation of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret in rat plasma..
Language:
English
Published:
Jundishapur Journal of Natural Pharmaceutical Products, Volume:8 Issue: 2, Jun 2013
Page:
81
magiran.com/p1148084  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!