Room acoustic analysis of blower unit and noise control plan in the typical steel industry

Message:
Abstract:
Introduction
In the steel industry،air blowers used to supply compressed air are considered as sources of annoying noise. This study aims to acoustics analysis of theairblower workroomand sound source characteristics in order to present noise controlmeasuresinthe steel industry.
Material And Method
Measurement of noiselevel and its frequency analysis was performed usingsound levelmetermodelof CASELLA-Cell. 450. Distribution of noise level in the investigated workroom in form of noise map was provided using Surfer software. In addition، acoustic analysis of workroom and control room was performed in view point of soundabsorption andinsulation. Redesignofdoor and window of controlroom and installation of soundabsorbing materialson theceiling of the workroom were proposed and the efficiency of these interventionswasestimated.
Result
The totalsound pressurelevelin the blower workroom was 95. 4 dB (L) and the dominant frequency was 2000Hz. Sound pressure level inside the room control was 80. 1dB (A). The average absorption coefficient and reverberation time in the blower workroom was estimated equal to 0. 082 Sab. m2 and 3. 9 seconds respectively. These value in control room was 0. 04 Sab. m2 and 3/4 seconds respectively. In control room، sound transmission loss between the two parts of the wall dividing was 13. 7 dB (A). The average of noise dose in blower operators was 230%. With the installation of sound absorber on ceiling of workroom، average of absorption coefficient can increase to 0. 33 Sab. m2 and sound transmission loss of the new designed door and window was estimated equal to 20dB.
Conclusion
The main cause of noise leakage in the control room was insufficient insulation properties of door and windows. By replacing the door and window and installation of sound absorbing on ceiling of workroom، the noise dose can reduce to 49. 6%. New Improved door and window of control room can reduce noise dose to 69. 65% solely.
Language:
Persian
Published:
Journal of Health and Safety at Work, Volume:2 Issue: 2, 2013
Pages:
41 to 50
magiran.com/p1176127  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!