Dynamics of Fluids in Vessels Extremist Cooling Load Calculations
Message:
Abstract:
Influential factor in the maintenance of defense systems، navigation equipment and navigation aid providing Ideal environment to increase the throughput and efficiency of the staff، the right choice is an air conditioning system in Extremist vessels. Due to the Persian Gulf and the different climate conditions in different parts of the region and the lack of attention to the problem of determining the design capacity of the vessels conditioning systems also need to optimize class Construction. Therefore، due to the low number of vessels conditioning system cooling capacity Extremist Ndsa sailing in different locations during missions and personnel grievances، to fix this problem Research and field work in the operating area of Bandar Abbas on the basis of scientific studies that took Methods and results are presented in this paper. This paper describes the types of HVAC systems on vessels Extremist with its advantages and disadvantages are reviewed. Cooling load calculation of three tables، engineering companies، marine engineering approach to relationships Science (calculation formula) and the calculation method on this class of vessels software Carrier Extremist perform together were compared. According to our calculations based on the methods and models over the floating cabin area and volume، sex walls Floating climatic conditions and other parameters that the software method nominal capacity of 30 000 Btu/h arrived. Previous conditioning system capacity on this class of vessels under 20 000 Btu/hours or 24 000 Btu/ hours. Due to the higher accuracy computational methods، software selection based on the capacity of cooling capacity conditioning system was studied in the float. After selecting the new system installation and field testing of the vessel، the new cooling capacity this class of vessel ideally suited for floating design provides needed ventilation. In this method، 10 to 15% as a safety factor to the calculated cooling load is added. The new cooling capacity can be used to optimize the results of previous vessels and conditioning systems such an increase can be used defensively and staff morale.
Language:
Persian
Published:
Iranian Journal of Marine Science And Technology, Volume:21 Issue:71, 2015
Pages:
30 - 41
magiran.com/p1351427  
روش‌های دسترسی به متن این مطلب
اشتراک شخصی
در سایت عضو شوید و هزینه اشتراک یک‌ساله سایت به مبلغ 300,000ريال را پرداخت کنید. همزمان با برقراری دوره اشتراک بسته دانلود 100 مطلب نیز برای شما فعال خواهد شد!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی همه کاربران به متن مطالب خریداری نمایند!