The Effect of Multiple Firing on the marginal gap and internal fit of Zirconia Frames to Dental Implant abutments

Abstract:
Introduction
Today, the use of all-ceramic restorations in dental implants has increased due to proper structural characteristics and excellent esthetics. For more beauty, zirconia frames might be exposed to repetitive firing cycles due to their unfavorable color, leading to increased lack of restoration compliance. Given the effects of marginal gap on inflammation around fixtures and implant failure, this study aimed to evaluate the effects of porcelain multiple firings on marginal gap and internal fit of zirconia frames to dental implant abutments.
Materials and Methods
In total, 40 abutments were selected and divided into four groups. In the first group, zirconia frames were fabricated at 0.4 mm diameter. The frames were cemented and marginal gap was measured after thermal cycles (magnification: 40X). In addition, the space between the abutment and crown, which was cut with a diamond disc, was measured in order to measure internal fit values (magnification: 40X). While the phases were similarly carried out for the second, third, and fourth groups, the samples were porcelain-fused for two, four, and six times before cementing the implant crown to the abutment, respectively. Moreover, the final porcelain thickness was estimated to be 2 mm, followed by the evaluation of the marginal gap parameters and internal fit values.
Results
In this study, the marginal gap value was reported to be 52-69 micrometers, while the internal fit value was 17-26 micrometers. In terms of marginal gap and internal fit of zirconia frames, no significant difference was observed in the samples after porcelain firing cycles, compared to those with no firing.
Conclusion
According to the results, zirconia was not significantly affected by porcelain firing cycle due to its high mechanical properties, as well as high strength and complete sintering. Moreover, no significant difference was observed in the compliance of zirconia frames with dental implant abutments after multiple firing cycles.
Language:
Persian
Published:
Journal of Mashhad Dental School, Volume:40 Issue: 3, 2016
Pages:
223 to 236
magiran.com/p1582193  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!