Evaluation of X-radiation beam quality characteristics of experimental and simulated surface

Abstract:
One of the most common methods used in radiation therapy for the treatment of superficial skin lesions using the ortho-voltage radiation X (the kVp 300), respectively. One of the most important indicators for the treatment of this type of device, the quality of the X-ray output is usually half the thickness of the absorption (HVL) Vanrzhy show photons effective. However, in this study, the coefficient of homogeneity was examined as a factor.
Materials And Methods
In this study, the half-absorption layer (HVL) and homogeneity coefficient of the X-ray surface voltage was determined kV180 experimental and simulated with Monte Carlo method and the results were compared with the EGSnrc code. Using the measured absorption curve for this exposure through the layers of the weakening of the clinic was drawn with appropriate interpolation of the curve, the half-absorption layer (HVL) and homogeneity coefficient, respectively. The package EGSnrc, the code BEAMnrc to simulate photon and electron transfer up to receive daily intravaginal and BEAMDP for coefficient homogeneity systematically and draw the output spectrum (using data from phase space code BEAMnrc) and the code DOSXYZnrc to trace the curve of percentage depth dose the water phantom was used. The results show that the mean percentage difference between the HVL and homogeneity coefficient obtained from simulation and experiment 2, 96/4% and 01/3%, respectively.
Conclusion
According to previous studies that measured HVL of difference between experimental and simulated 2% to over 10% were reported as the mean difference between the 96/4%, respectively. The difference is that this is reasonable. Homogeneity coefficient was calculated from the above previous reports due to differences in the code is justified. Considering the limitations of the clinics, the present method because of the simplicity of the layout and the similarity of the clinical conditions seem to have good performance.
Language:
Persian
Published:
Razi Journal of Medical Sciences, Volume:23 Issue: 10, 2017
Pages:
43 to 51
magiran.com/p1659864  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!