Radiation Dose and Image Quality Assessment of the Bolus Timing Method for CT Angiography

Abstract:
Background
Bolus timing monitoring scans used for computed tomography angiography (CTA) repetitively expose the same region of the body to radiation with a view to determining the appropriate threshold attenuation level of the contrast material (CM). Therefore, for an effective CT scan, it is necessary to minimize repetitive radiation exposures from bolus timing.
Objectives
This study aims to effectively identify and reduce the radiation dose needed for repetitive monitoring scans utilized in CT involving the bolus timing method.
Patients and
Methods
To investigate the currently employed protocols and the number of monitoring scans in bolus timing CT studies, 983 patients (581 males and 402 females; mean age 62.7) were retrospectively analyzed from October 1, 2013 to March 31, 2014. To identify the appropriate kVp and mA change in the hounsfield unit (HU) and measure the contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) in the bolus timing method, a 2 mL syringe containing CM diluted with saline at a ratio of 1 to 300 was inserted into cavities of a CT dose index (CTDI) head phantom and scanned with a 64-section multi-detector row CT system. The dose variation was analyzed using results from the ionization chamber and CTDI.
Results
This retrospective analysis of bolus-timing CT studies found that patients underwent an average of 4.5 to 5.4 monitoring scans. Furthermore, while the HU value of the mixed CM syringe in the central CTDI head phantom cavity was inversely proportional to mA, the decrease in the HU value became weaker at a value of 50 mA with 100 kVp and at 30 mA with 120 kVp. Here, the CNR (Pearson correlation r = 0.983, Kendall’s t = 0.978, P
Conclusion
It is recommended that minimum level of radiation (100 kVp, 50 mA; 120 kVp, 30 mA) at which the HU value at the trigger threshold is not significantly different from that of the actual helical scans should be used to minimize the radiation dose caused by repetitive monitoring scans in the bolus timing method.
Language:
English
Published:
Iranian Journal of Radiology, Volume:14 Issue: 2, Apr 2017
Page:
4
magiran.com/p1715297  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!