M O D I F I E D S T R E S S-S T R A I N M O D E L S O F C O N C R E T E C O N F I N E D W I T H F R P U N D E R C O N C E N T R I C A N D E C C E N T R I C L O A D I N G S
Author(s):
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Wrapping reinforced concrete columns with composite materials is among the new methods of repairing and strengthening at the moment. There are several analytical relationships for load capacity prediction of strengthened columns with this method under compressive load in the literature, but, columns that are on the border of buildings are usually subjected to combined axial-flexural loading in practice. According to strain gradient in the columns under eccentric loading, the FRP confinement effect is different and changing with the load eccentricity. A few relationships for load capacity calculation of strengthened columns under eccentric loading are presented, some models in the literature are in contradiction with each other. This paper presents constant factor, FRP strain efficiency factor in the model, proposed by Lam and Teng, which is modified for specimens under centric loading, varying according to the type of FRP. It has been shown in this study that the constant factor is not only dependent on FRP type, but it also depends on the FRP elastic modulus to unconfined concrete compressive strength ratio. With this modification, total error value of 76 specimens under centric loading will decrease from 10.63 to 9.5 percent.Then, correction factor is analyzed to apply the load eccentricity to the existing models and compare them with available experimental results. This correction factor shows that compressive strength of confined concrete under eccentric loading increased by increasing in the load eccentricity. By applying this coefficient to the model by considering the load eccentricity and calculating the load carrying capacity of specimens, the total error of specimens under eccentric loading decreases from 11 to 6 percent. This factors is determined using Genetic algorithms by optimizing the difference between experimental results and theoretical values. Comparison of results of tests with modified model, demonstrates that modified models in this study provide a better prediction for wrapped columns under concentric and eccentric loadings.
Keywords:
Language:
Persian
Published:
Sharif Journal Civil Engineering, Volume:33 Issue: 4, 2018
Pages:
61 to 69
magiran.com/p1823919
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یکساله به مبلغ 1,390,000ريال میتوانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
- حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران میشود.
- پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانههای چاپی و دیجیتال را به کاربر نمیدهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required
Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!