Water pump noise control using designed acoustic curtains in a residential building of Qazvin city

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background And Aims
Using water pump in residential buildings to provide the required water pressure is accompanied by noise pollution and the annoyance of residents. So, the purpose of this study is to reduce water pump noise pollution with designed acoustic curtains in a residential building of Qazvin city.
Methods
The mean sound pressure level was measured before and after control intervention around the sound source based on ISO 9612, using the sound level meter (Casella-Cell.450). The sound level meter was calibrated using a calibrator(Cell-110/2). The frequency analysis was done in 1.1 octave band and the weighting frequency of A. Acoustical features of acoustic curtains (thickness, material and dimensions)were determined on the base of required sound transmission loss in predominant frequency. The volumetric flow of air required to decrease the temperature inside the enclosure up to 40°C to maintain a reasonable air temperature for pump performance was calculated using the energy-mass conservation law. Temperature inside the enclosure was measured with a mercuric thermometer.
Result
The mean sound pressure level before and after control around the pump was measured 67 dBA and 46 dBA respectively. The required insertion loss in predominant frequency(2000 Hz) to accommodate noise limit in residential buildings was considered to be 26 dB and based on which acoustic curtain surface density was calculated between. The average sound pressure level measured after control(46dBA) with predicted sound pressure level by mathematical calculation after control(47dBA) was not significantly different. The volumetric flow rate required to maintain a temperature of 40°C inside the enclosure was calculated to be 1.2 cubic meters per minute. The temperature was measured inside the enclosure of 38° C.
Conclusion
Control of noise pollution using acoustic curtains with a lower cost and weight, higher installation speed and higher sealing can be considered as one of the proper methods for enclosing noise resources.
Language:
Persian
Published:
Iran Occupational Health, Volume:15 Issue: 1, 2018
Pages:
126 to 135
magiran.com/p1835696  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!