REHABILITATION ASSESSMENT OF REINFORCED CONCRETE FRAME WITH STEEL PLATE SHEAR WALLS DUE TO DIFFERENT CONNECTION METHODS
Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:

In recent years, the use of thin Steel Plate Shear Walls (SPSWs), for rehabilitation of existing reinforced concrete (RC) structures has increased due to their significant resistance, stiffness, ductility, and energy dissipation capacity. The main issue in the rehabilitation of RC structures with SPSWs, is the necessity of the existence of a suitable connection between SPSW and the RC frame (RCF), so that the tension field of SPSWs can well be transferred to the RCF and steel infill plate capacity can well be used. In this study, different proposed connections between SPSW and RCF are studied.After the verification of the experimental specimen, one- span three-story special RCF with SPSW with one-third scale, specimens were modeled by the proposed connections. Four types of connection were investigated for connecting the steel infill plate to RCF. All specimens were analyzed by non-linear static analysis. Parametric studies were performed to achieve an optimum connection. The parameters include using bolts in columns and beams, thickness of plate connections, using the angle profiles in the corner columns and size of angle profiles connected to steel infill plates.Based on the modeling results, a comparison of the values of the ductility, elastic stiffness, energy dissipation capacity, and load-carrying capacities of specimens with different connections, indicated a significant increase in the values of initial RCF. Increasing the thickness of the plates connected to beams and columns and the growing use of the angle profiles in the corner columns improve the performance of the connections; however, do not lead to a considerable increase in resistance and non-economic causes of the connection. By comparing the performances of different connections, an appropriate connection was proposed. Based on the results of all specimens, response modification coefficient and over strength factor of special RCF with thin SPSW were estimated at 8.37 and 2, respectively, as compared with the values of the proposed the ASCE 7-10, for dual system of special steel frame with SPSW.

Language:
Persian
Published:
Sharif Journal Civil Engineering, Volume:35 Issue: 1, 2019
Pages:
55 to 66
magiran.com/p1996191  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 990,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 50 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!