Abstract:
Background
The present study aimed to replace the integrated sound level meter by the noise map of a work environment in order to estimate the equivalent continuous sound level (Leq) as an important quantity in the noise monitoring of continuous noise sources.
Methods
In this theoretical-experimental study, the grid method was initially used. Sound pressure level (SPL) was measured at the selected stations in three noisy industrial halls. Data analysis was performed in ArcGIS 10.2 software, and the noise map was plotted for each hall separately. Afterwards, the different zones with various SPL intervals were calculated on each noise map, and Leq was determined. For the comparisons, Leq was also calculated using logarithmic equations, based on which the integrated sound level meters were programmed.
Results
The proposed method was highly accurate with the relative error of less than 2%. Furthermore, it decreased the number of mathematical operations 7-15 times compared to the conventional logarithmic method.
Conclusion
According to the results, the available GIS-based software could be accurately replaced by the routine Leq measurement hardware to estimate the Leq spatial noise in noisy industrial environments.
Language:
English
Published:
Journal of Human, Environment and Health Promotion, Volume:5 Issue:2, 2019
Pages:
50 - 55
magiran.com/p2029834  
روش‌های دسترسی به متن این مطلب
اشتراک شخصی
در سایت عضو شوید و هزینه اشتراک یک‌ساله سایت به مبلغ 300,000ريال را پرداخت کنید. همزمان با برقراری دوره اشتراک بسته دانلود 100 مطلب نیز برای شما فعال خواهد شد!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی همه کاربران به متن مطالب خریداری نمایند!