Background

The computer-aided diagnosis (CAD) has been applied in multiple studies conducted recently in order to perform ultrasound (US) of the breast. There are several studies that have indicated that CAD is useful for improving the diagnostic performance in less experienced radiologists. However, there is no study on several readers analyzing the same lesions using a breast phantom and rare reliability studies.

Objectives

To investigate the reliability of different readers using computer aided diagnosis (CAD) system in US for determining identical lesions in a breast phantom. Patients and

Methods

From March 2016 to February 2017, six readers (three senior and three junior residents in the department of radiology) evaluated and analyzed breast phantom including 14 lesions. At the first line study, three senior residents (3rd grade with more than one month of training for breast ultrasound [US]) and three junior residents (1st grade without breast US training) evaluated and analyzed the US and applied CAD for lesions in breast phantom, and they were able to make final decisions by subjective combination. A month later, they conducted the second line study as they did the first line study. We analyzed the inter- and intra-reader reliability and accuracy of US, CAD, and combinations (subjective, conjunctive, and disjunctive).

Results

In the total of first and second line studies of six readers, the kappa value of US (0.609) was significantly higher than CAD (0.411). In the subjective combined conclusion, the kappa value was improved by the junior group. In the whole inter- and intrareader analysis, the kappa values of final assessment of the senior and junior group weremorevariableonCADthanonUS, especially in the junior group, and this result was statistically significant. The area under the curve (AUC) of US, CAD, subjective, conjunctive, and disjunctive combination in seniors were all better than those of juniors. In all groups, the AUCs, sensitivities, and specificities were improved on conjunctive combined US with CAD.

Conclusion

The combination US with CAD improved the reliability and diagnostic performance. The CAD results of the junior group were variable and inconsistent. Therefore, minimum training and experience for breast US is indispensable for the better use of breast CAD, and, combination US with CAD is useful for all readers.

Language:
English
Published:
Iranian Journal of Radiology, Volume:16 Issue: 4, Oc 2019
Page:
10
magiran.com/p2050933  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!