Ductility Evaluation of inverted V-bracing and concentrically bracing systems
Author(s):
Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
The current design philosophy for buildings located in zones with high seismic risks is that the buildings must have sufficient strength and stiffness to remain elastic and serviceable under moderate but frequently occurring earthquakes and to have sufficient ductility to prevent collapse under extreme earthquakes. Conventional structural steel framing systems such as moment resisting frames (MRFs), concentrically braced frames (CBFs), and eccentrically braced frames (EBFs) I extensively used in seismically active areas. Each of the previously mentioned structural systems has different advantages and disadvantages.In this study, response modification factor of ordinary inverted V-braced frames and specially inverted V-braced frames are evaluated, result confirm that the proposed height for buildings with ordinary inverted braced frames in the ASCE7,can be increased up to 10.7 meter. also results indicate that by using ordinary inverted V-bracing systems in buildings .their height can be increased up to 6 story or 20 meter. Using special inverted V-braced systems can have saving about 0 to 30 percent on used materials for frames from 1 story to 16 stories. According to the results of this study, response modification factor proposed by Iranian seismic design code (2800 standard fourth edition),(R=5.5), is more logical than the one which is proposed by ASCE7, (R=6). Unfortunately, in special inverted V-braced frames, and when the story of the frames increases up to 12 stories, ductility demand can't be achieved .So as a result for frames which are more than 12 stories tall, lower response modification factor should be used. In addition, frames taller than 12 story height don’t experience specified target displacement and collapse before getting to preferred mechanism. This phenomenon shows the necessity of using different response modification factor for frames taller than 12 stories.
Language:
Persian
Published:
Journal of Structural and Construction Engineering, Volume:6 Issue: 2, 2019
Pages:
175 to 190
magiran.com/p2054355  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 990,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 50 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!