Design of an Inhalation Chamber to Expose Laboratory Animals with Suspended Particulate Matter by Numerical Simulation Method

Message:
Abstract:
Introduction
Usually, in the toxicological studies of airborne particulate pollutants, inhalation exposure chambers are used for providing and distributing the test atmosphere uniformly and stability in the respiratory zone of laboratory animals. The purpose of this study was to design, evaluate and optimize a whole-body exposure chamber, specifically for small laboratory animals exposed to particulate matter.
Material and Methods
In the first, the papers and scientific resources which had provided the technical details and performance of the inhalation exposure chambers were studied, and the advantages, disadvantages and those factors affecting their performance were extracted. Then the assumptions of the initial design of the chamber were prepared with regard to the principles of fluid dynamics and the standard conditions of lab animal housing. To create a uniform distribution of particles inside the chamber, guide plates of flow were used in the upper cone. Numerical simulation and ANSYS Fluent software were used to optimize the initial design. Drawing geometry of the chambers was done using Design modeler software and meshing of the computational field using ANSYS meshing software. The particles used had a mean aerodynamic diameter of 10 μm, spherical, inert, and a density of 1,400 kg. m^-3 and entered the chamber at the carrier gas velocity. Particle concentration was measured in the chambers along the cylindrical radius at 10 cm intervals on the x-axis. Then the percentage of variation coefficient of the particle concentration for each line was calculated. In the final analysis of the results, the geometry design with the lowest coefficient of variation of particle concentration along the selected sampling line was selected as the best chamber design.
Results
The optimized inhalation chamber has a dynamical flow and consists of a cylinder with two upper and lower cones. The flow enters from the upper cone and after passes through the guide plates, distributes in the interior of the chamber and exits from the lower cone. The k-ε turbulence and Discrete Phase Models could have modeled this problem. Design No. 7 was optimal design with the lowest coefficient of variation of the concentration (4.08%).
Conclusion
The numerical simulation method for planning and optimizing of the chambers, at a much lower cost than the empirical methods, was able to provide comprehensive information on the solution field. The analysis of this information led to the selection of the best chamber design to provide uniform concentration of the particles in the respiratory region of the animals.
Language:
Persian
Published:
Journal of Health and Safety at Work, Volume:9 Issue: 4, 2019
Pages:
346 to 362
magiran.com/p2071093  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!