Abstract:
Fluid storage tanks, especially above ground tanks, are categorized as important and essential in energy infrastructure. These storages, which are mostly used to store petroleum fluids and fire water supplies, are therefore of great importance to the exploitation of tanks after the earthquakes. Fragility or vulnerability curve is one of the most effective tools for estimating the damage caused by the earthquake. Preparing the seismic fragility curve of above ground tanks on a pile is the aim of this research. This fragility curve is achieved regardless of tank body damage and only by focusing on the structural behavior of the foundation. These tank types are primarily built on low load bearing areas. In this study, three tank types that have been designed in accordance with API650-13 have been investigated in a practical project. For this purpose, using the static nonlinear analysis method, the structural capacitance curve of tanks was first obtained. Then, the seismic performance of these tanks was obtained for 12 spectra from different records with different accelerations. After calculating the damage indexes on the structure, the appropriate statistical distribution for the failure criteria was chosen. Finally, the calculation of the probability of failure for the fracture curve of the required tanks was obtained Fluid storage tanks, especially above ground tanks, are categorized as important and essential in energy infrastructure. These storages, which are mostly used to store petroleum fluids and fire water supplies, are therefore of great importance to the exploitation of tanks after the earthquakes. Fragility or vulnerability curve is one of the most effective tools for estimating the damage caused by the earthquake. Preparing the seismic fragility curve of above ground tanks on a pile is the aim of this research. This fragility curve is achieved regardless of tank body damage and only by focusing on the structural behavior of the foundation. These tank types are primarily built on low load bearing areas. In this study, three tank types that have been designed in accordance with API650-13 have been investigated in a practical project. For this purpose, using the static nonlinear analysis method, the structural capacitance curve of tanks was first obtained. Then, the seismic performance of these tanks was obtained for 12 spectra from different records with different accelerations. After calculating the damage indexes on the structure, the appropriate statistical distribution for the failure criteria was chosen. Finally, the calculation of the probability of failure for the fracture curve of the required tanks was obtained.
Language:
Persian
Published:
Civil Infrastructure Researches, Volume:5 Issue: 1, 2019
Pages:
51 to 60
magiran.com/p2086818  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!