The Effect of Type and Size of Single, Twin, and Triplet Flat Fan Nozzles on the Activity of Cycloxydim against Wild Barley (Hordeum spontaneum Koch.)

Author(s):
Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Introduction

The herbicide application has caused some environmental problems. Therefore, optimal application of herbicides was followed in recent years. For this purpose, it is essential to minimize the exo-drift and/or endo-drift of spray droplets. The amount of exo-drift and/or endo-drift is directly related to the size of spray droplets. By decreasing the size of spray droplets, the exo-drift increases and the endo-drift decreases (34). This intricate issue is a stimulus to develop the types of nozzles in different sizes (color) producing different sizes of spray droplets at different spraying pressures. Such a development in the production of nozzles has caused difficulty and confusion in selecting a suitable type of nozzle (2). On the other hand, the agriculture sector is faced with water crisis in recent years. Considering that water is the most important carrier of herbicides, selecting a suitable spray volume is thus necessary. According to previous studies (26), the efficacy of different herbicides can influence spray volume negatively (30), neutrally (29), or positively (12). So far, the effect of spray volume on the efficacy of cycloxydim against any weed has not been investigated. Also, since the types of triplet flat fan nozzles have been recently developed, no investigation has been done on their performance compared to the types of single and twin flat fan nozzles. The current study aimed to fill this knowledge gap.   

Materials and Methods

The seeds of wild barely (Hordeum spontaneum Koch.) were treated to germinate. Then, 8 seedlings were planted within each 3-L pot and grown in the Research Greenhouse of Bu-Ali Sina University, Hamedan, Iran. At the four-leaf stage, they were treated with 0, 6.25, 12.5, 25, 50, and 100 g cycloxydim ha-1 using 3 nozzle types (i.e. Standard, Anti-Drift, and Air Induction), at 3 orifice numbers (i.e. single, twin, and Triplet) and 3 nozzle sizes (i.e. 11002, 11003, and 11004). The treatments were sprayed at a pressure of 300 kPa when the wind speed was less than 0.4 m s-1. The volume of spray created by 11002, 11003, and 11004 nozzle sizes was 160, 240 and 320 L ha-1, respectively. Three weeks after spraying, the dry weight of plants was determined. The date were fitted using a four-parameter log-logistic model to estimate the dose required to achieve 50% wild barley control (ED50).
 

Results and Discussion

The ED50 was significantly affected by the type, size, and orifice number of nozzle. In all types of nozzles (Standard, anti-Drift and Air Induction) and sizes (11002, 11003 and 11004), an increase in orifice number significantly reduced the values of ED50 for cycloxydim against wild barely, indicating increased efficiency of herbicide. This can be explained by two reasons. Firstly, with an increase in orifice number in each type of nozzles, the size of spray droplets decreases. Previous studies have proven that there is a negative relationship between the amount of spray droplets deposited on the target surface and the size of spray droplets. Therefore, by decreasing the size of spray droplets, they can be deposited more on the target surface, resulting in an improvement in the foliage-herbicides efficiency. Secondly, increasing the orifice number of nozzle can lead to the penetration of spray droplets into the canopy. Among the nozzles of 11002 in any orifice number, the performance of nozzles was ranked as Standard > Anti-Drift > Air Induction. However, among the nozzles of 11003 or 11004 in any orifice number, the performance of nozzles was as Standard = Anti-Drift > Air Induction. Among all types of nozzles in any orifice number, increasing spray volume from 160 to 240 L ha-1 reduced the ED50. However, only in the types of nozzles of Air Induction in any orifice number, increasing spray volume from 240 to 320 L ha-1 reduced the ED50. 

Conclusion

It can be recommended that the most suitable nozzle for the application of cycloxydim against wild barely at a wind speed of less than 0.4 m s-1 with the aim of optimizing simultaneously both the dose of herbicide and the consumption of water is "Triplet Standard Flat Fan Nozzle 11003 " (spray volume= 240 L ha1).

Language:
Persian
Published:
Journal of plant protection, Volume:33 Issue: 4, 2020
Pages:
465 to 474
magiran.com/p2098839  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!