Salvage of Suboptimal Enhancement of Pulmonary Artery in Pulmonary CT Angiography Studies: Rapid kVp Switch Dual Energy CT Experience

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background

Multidetector computed tomography (MDCT) angiography is considered as the gold standard imaging modality in the evaluation of acute pulmonary embolism. Optimum vascular enhancement is critical for MDCT studies. The suboptimal opacification in pulmonary artery could be salvaged using low-energy virtual monoenergetic images (VMI) at rapid kVP switch dual energy CT.

Objectives

To explore the potential improvement in pulmonary artery opacification and to assess the change in image quality parameters in VMI using fast switch kVp dual energy CT. Patients and

Methods

The CT images of 877 patients who were referred with a preliminary diagnosis of pulmonary embolism were reviewed. Sixty patients with suboptimal enhancement (< 200 Hounsfeld Unit [HU]) were involved. Standard images (140 kVp) and VMI from 40 to 120 keV were generated. Attenuation, noise, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were measured in the pulmonary artery. Using VMIs, the best image was determined as the image with the main pulmonary artery opacification greater than 200 HU and image quality ≥ 3. Fifty six studies that met these criteria were considered as salvaged. At this best energy level, quantitative parameters were compared with standard images.

Results

The mean attenuation of pulmonary arteries was 169.80 HU in standard images in patients with suboptimal enhancement. The attenuations of VMIs at 40, 45, 50, 55, 60, 65, and 70 keV were significantly higher than standard images (P < 0.001). Similar findings were observed with SNR and CNR. In the salvaged patients, the average increase in mean pulmonary artery attenuation was 62% (from 172.61 ± 23.4 to 280.55 ± 40.7), the average increase in SNR was 38% (from 12.1 ± 5.3 to 16.7 ± 7.1) and the average increase in CNR was 48% (9.2 ± 4.3 to 13.7 ± 6) (P < 0.001).

Conclusions

Low keV VMI reconstructions significantly increase pulmonary artery attenuation, CNR and SNR compared to standard image reconstructions. Suboptimal CT studies could be salvaged using low keV VMIs.

Language:
English
Published:
Iranian Journal of Radiology, Volume:17 Issue: 2, Apr 2020
Page:
13
magiran.com/p2120906  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!