Assessment of the Intermediate Cavity Impact on the Cooling Energy Performance of the Multi-Story Double-Skin Facade in Hot and Humid Climate (Kish Island)

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
The majority of the energy exchanges in buildings are dependent on or at least related to the exterior skin of the building. The exterior skins are the localities of the building’s heat exchange with the peripheral environment, solar energy absorption, ventilation, and light and sound infiltration to the interior environment. These spots play an important role in energy savings in buildings. The double-skin facades have been considered a solution to create transparency, control the effect of the environment on the building, and its useful performance in terms of climatic consistency and energy consumption. Given the heat pileup problems stemming from the greenhouse effect of the intermediate cavity, especially in hot and humid climates; it was deemed necessary to carry out a study to figure out the optimum clearance between two skins to reduce energy consumption. The present study is conducted using information collection, simulation of case study with Design builder software, and analysis of the quantitative data obtained from the simulation of the studied buildings in the hot and humid climate of Kish Island. The multi-story DSF is simulated at various distances between the two skins to investigate the amount of cooling energy consumption. The research findings show the amount of cooling energy used at cavity intervals of 30 to 200 centimeters. The research theoretical foundation is laid on the idea that the southern front of the multi-story DSF, compared to the various types of DSF, has a considerable effect on the optimum conditions of the reduction in energy consumption. The results of this study indicate that the cavity depth plays an important role in the reduction of cooling energy, and a double skin facade with the depth of 50 to 70 centimeters is the optimum distance in reducing cooling energy consumption, compared to other intervals in the low-rise office building in the hot and humid climate
Language:
Persian
Published:
Journal of Architect, Urban Design & Urban Planning, Volume:13 Issue: 30, 2020
Pages:
19 to 29
magiran.com/p2136192  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!