The reliability of cephalometric measurements in orthodontics: Cone beam computed tomography versus two-dimensional cephalograms

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background and Purpose

 Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms and CBCT scan measurements in linear orthodontic diagnostic measurements.

Materials and methods

In the first part, the distances between the 14 anatomical landmarks on the 5 dried human skulls (reference models) identified by metal spheres were measured by a digital caliper. In the next step, CBCT images were scanned from the same reference models. In the second part, radiographic images were taken from 26 patients enrolled according to inclusion and exclusion criteria in three stages, scanning CBCT images, digital LC (Lateral Cephalometric) images from the same CBCT images, manual tracing of digital LC images. Finally, using the obtained data, the accuracy of measurements performed directly on the reference models with CBCT images as well as the CBCT images, digital LC and traced digital LC images of the patients were evaluated together.

Results

The mean of direct measurements on the reference models was not significantly different from the measured values on CBCT images (ρ-value> 0.05). In other words, the measurement of the CBCT images was the same as the reference models. Also, in most cases, linear measurements between the traced LC image with digital LC images and the CBCT of patients were different (ρ-value > 0.05). Meaning traced LC images and digital LC in 8 cases, CBCT and digital LC in 4 cases and finally traced digital LC and CBCT in 5 cases were different.

Conclusion

The present study showed that the accuracy of CBCT image measurements was similar to the direct measurements obtained from the reference models. Also, the accuracy of linear measurements of CBCT images is higher and more reliable than that of digital LC images as well as traced digital LC images.

Language:
English
Published:
Journal of Dentomaxillofacil Radiology, Pathology and Surgery, Volume:9 Issue: 1, Spring 2020
Pages:
36 to 43
magiran.com/p2141565  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!