Comparative Evaluation of Contamination to Coliforms and E.coli in Foods by Using Different Chromogenic Medias and Their Correlation with Reference Method
Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:

Various methods have been developed to detect the presence of contamination with Coliforms and E. coli in foods. The pour plate technique using VRBA medium is confirmed as a standard method in Iran. The biggest disadvantage of this method is the need to spend a lot of time, high volume of laboratory operations, multiple stages and ultimately long time to achieve the results. Today, due to the mass production of various foodstuffs, the need for faster methods with high sensitivity to control the quality of food is necessary for the responsible oversight centers. The use of chromogenic medias is also one of the fastest diagnostic methods that have been developed. According to this matter, a comparative study was considered from the results of application of three chromogenic media and reference method in food quality control. Totally 100 samples of foodstuffs were evaluated for contamination to Coliform and E.coli using standard method and three chromogenic medias. Based on the obtained results, 86, 79, 85 and 80 samples were contaminated to Coliform using the standard method, Coliform Agar ES, ChromAgar ECC and Rapid E.coli 2/Agar respectively. Also, using four mentioned methods, contamination to E.coli was reported at 66, 80, 84 and 80, respectively. Cochrane test showed that there was no significant difference between the four methods in Coliform diagnosis (p>0.05). However, four methods did not have the same function in the detection of E. coli so that the chromogenic methods showed significant difference with the standard method (p< 0/001). But there was no significant difference between these chromogenic methods in detecting E.coli (p>0.05). According to the statistical analysis of present study, three chromogenic medias can be used instead of the standard method for the detection of Coliform, but the use of these chromogenic medias is not recommended for the identification of E.coli.

Language:
Persian
Published:
Food Science and Technology, Volume:17 Issue: 6, 2020
Pages:
191 to 200
magiran.com/p2164519  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 990,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 50 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!