Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Message:
Abstract:
Background

The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. 

Materials and Methods

An image-based deconvolution technique was proposed, incorporating wavelet-based denoising within the Lucy-Richardson algorithm to jointly compensate for PVEs and respiratory motion. The method was evaluated using data from 15 patients with 60 non-small cell lung cancer. In these patients, the lesions were classified by size, location and Signal-to-Background Ratios (SBR). In each study, PET images were reconstructed using four different

methods

OSEM with time- of-flight (TOF) information, OSEM with point spread function modelling (PSF), OSEM with both TOF and PSF (TOFPSF), and OSEM without PSF or TOF (OSEM). The Contrast to Noise Ratio (CNR), Coefficient of Variation (COV) and Standardized Uptake Values (SUV) were measured within the lesions and compared to images that were not processed using the joint-compensation technique. Furthermore, variabilities arising due to the choice of the reconstruction methods were assessed.

Results

Processing the images using the proposed technique yielded significantly higher CNR and SUV, particularly in small spheres, for all the reconstruction methods and all the SBRs (P<0.05). Overall, the incorporation of wavelet-based denoising within the Lucy Richardson algorithm improved COV and CNR in all the cases (P<0.05.( In the patient data, the median values of the relative difference (%) of CNR for the compensated images in comparison to the uncompensated images were 40.9%, 41.2%, 45.3% and 40.8% for OSEM, PSF, TOF, and TOFPSF, respectively, in the small lesions (equivalent diameter <15 mm), 31.0%, 25.9%, 34.1% and 28.2% in the average-sized lesions (equivalent diameter<30 mm), 35.7%, 33.7%, 37.8% and 33.2% in the lesions in the lower lung lobes, 33.5%, 31.0%, 35.7% and 30.6% in the lesions in the upper lung lobes, 39.7%, 37.9%, 45.1% and 39.0% in the low-SBR lesions and 28.8%, 27.8%, 34.8% and 25.7% in the high-SBR lesions. Changes in motion amplitude, target size and SBRs in the patient data resulted in significant inter-method differences in the images reconstructed using different methods. Specifically, in a small target size, quantitative accuracy was highly dependent on the choice of the reconstruction method.

Conclusion

Our results showed that joint compensation, and incorporation of wavelet-based denoising, yielded improved quantification from PET images. Quantitative accuracy is greatly affected by SBR, lesion size, breathing motion amplitude, as well as the choice of the reconstruction protocols. Overall, the choice of reconstruction algorithm combined with compensation method needs to be determined carefully.

Language:
Persian
Published:
Iranian South Medical Journal, Volume:25 Issue: 4, 2022
Pages:
355 to 370
magiran.com/p2513716  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!