Experimental Study on Wind Load and Wind-Induced Interference Effect of Three High-Rise Buildings

Author(s):
Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Wind loads of high-rise buildings are a key parameter in architectural design. The magnitude and distribution characteristics of wind loads are of great importance for the safety and economy of structural design. The wind loads of high-rise buildings are quite different from those of monomer buildings. The wind-induced interference effect could significantly increase the local wind pressure of buildings, causing potential safety hazards for the main structure and enclosure structure. For the three common high-rise buildings, we adopted the wind tunnel test method to measure the surface pressure of each building. The corresponding Re number was 8.2×106. This paper studied the shape coefficients, fluctuating wind pressure coefficients and base bending moment coefficient of each building with different wind direction angles and different spacing ratios, and the maximum value of each parameter and the corresponding working condition were statistically analyzed. The results showed that, under any wind direction angle, the fluctuating wind pressure coefficients on all sides of the building were affected by the spacing ratio, and the fluctuation range was large. When the wind angle was 180º, the fluctuating wind pressure coefficients on the sides of Building 1 were most affected by the slope ratio. At this wind angle, the maximum value was 0.43 at a slope ratio of 5.0, which was 65% different from the minimum. Partition shape coefficients of some sides and top surfaces changed significantly with the spacing ratio. When the spacing ratio was 5.0, the base bending moment coefficients in the downwind and crosswind directions reached their maximum values, and the wind direction angles where the maximum values of the base bending moment coefficients in the downwind direction were 40º and 50º, respectively, and the wind direction angle where the maximum value of the base bending moment coefficients in the crosswind direction was 10º. Due to the influence of the wind angle and the building spacing ratio, the wind loads on the facades of the pyramidal group of buildings varied greatly, and the wind-induced interference effect was evident. The wind load between the building facades in the three buildings was different, and the wind disturbance effect was evident. Therefore, the most unfavorable stress state and interference state of the structure should be comprehensively considered in the wind resistance design of the three buildings. The building spacing ratio should preferably be set to 3.0, and wind angles of 10º, 40º, and 50º should be avoided whenever possible.
Language:
English
Published:
Journal Of Applied Fluid Mechanics, Volume:16 Issue: 11, Nov 2023
Pages:
2101 to 2114
magiran.com/p2613146  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!