Reliability of Determination of Bony Landmarks of the Distal Femur on MR Images and MRI-Based 3D Models

Message:
Abstract:
Background/
Objective
Consistent determination of the anatomical landmarks on image or image-based three dimensional (3D) models is a basic requirement for reliable analysis of the human joint kinematics using imaging techniques. We examined the intra- and inter-observer reliability of determination of the medial and lateral epicondyle landmarks on 2D MR images and 3D MRI-based models of the knee.
Materials And Methods
Sixteen coronal plane MRI recordings were taken from 18 healthy knees using a knee coil with T2-weighted fast spin-echo sequence and 512×512 pixel size. They were then processed by the Mimics software to provide the coronal and axial plane views and to create a 3D image-based model of the femur. Each image was reviewed twice, at least one-day apart. The interclass correlation coefficient, standard error of measurement, and coefficient of variation were calculated to assess the intra- and inter-observer reliability of the landmark determination by six experienced radiologists. A mixed model analysis of variance (ANOVA) with two days of observation as the within-subject factor, and observers (six radiologists) and methods (2D vs. 3D) as between-subject factors were used to test the effect of observer, two days of observation and method of evaluation on landmark determination.
Results
The results indicated that the interclass correlation coefficients for the intra-observer and inter-observer determination of landmarks on images and image-based 3D models were above 0.97. The standard error of measurement ranged between 0.41 and 0.78 mm for x; 1.35 and 3.43 mm for y; and 1.03 and 4.71 mm for z coordinates. Furthermore, the results showed no significant difference for within and between-subject comparisons of each coordinate of the lateral epicondyle as well as x and z coordinates of the medial epicondyle. For the y coordinate of the medial epicondyle, the p value of within-subject comparison was borderlinely significant (p=0.049).
Conclusion
It was concluded that the intra- and inter-observer reliability of the bony landmark determination on both image and image-based 3D models were excellent.
Language:
English
Published:
Iranian Journal of Radiology, Volume:6 Issue: 4, Autum 2009
Pages:
225 to 230
magiran.com/p709988  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
دسترسی سراسری کاربران دانشگاه پیام نور!
اعضای هیئت علمی و دانشجویان دانشگاه پیام نور در سراسر کشور، در صورت ثبت نام با ایمیل دانشگاهی، تا پایان فروردین ماه 1403 به مقالات سایت دسترسی خواهند داشت!
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!