Occupational Radiation Exposure in Anesthesia Personal from C-Arm Fluoroscopy during Orthopedic Surgical Procedures

Message:
Abstract:
Background

The present study aimed to evaluate and analyze the amount of radiation received by anesthesiologists and anesthesia personal in Alzahra Hospital, Isfahan, Iran, using standard precautionary measures, to assess determinants for personal receiving high doses during orthopedic surgeries.

Methods

Ten people were included in a three month prospective study for radiation exposure measurement with adequate protection measures in all procedures requiring C-Arm fluoroscopy. Each person was provided with three Thermo Luminescent Dosimeter (TLD) badges which were tagged at the levels of neck, chest and gonads. Operating and exposure times of each procedure were recorded. Exposure dose of each badge at the end of the study was obtained and the results were analyzed. To measure dose, TLD cards containing CaS04 detectors were used. To read the data from TLDs, a TLD reader (Solaro2A) was used.

Findings

Mean radiation exposure to all the parts were well within permissible limits. There was a significantly positive correlation between the exposure time and the exposure dose for the orthopedic surgeon (r = 0.647; P < 0.01) and orthopedic residents (r = 0.49; P < 0.05). The orthopedic surgeon and residents had the maximum exposure overall. For the group of anesthetist, anesthesia resident and anesthesia nurse, the mean radiation exposure was less than the others. It was founded that the mean of absorbed dose for each fluroscopy on thyroid was 5.21 ± 2.56 mrad for the orthopedic surgeon, 1.13 ± 1.11 mrad for anesthesiologist, 1.22 ± 1.19 mrad for anesthesia resident and 1.39 ± 1.33 mrad for anesthesia personnel.

Conclusion

The mean exposure doses to all parts of the body of anesthetist and co-workers were well within the permissible limits. It is thus desirable that radiation safety precautions should be taken and exposures should be regularly monitored with at least one dosimeter for monitoring the whole-body dose.

Language:
Persian
Published:
Journal Of Isfahan Medical School, Volume:33 Issue: 360, 2016
Pages:
2013 to 2018
magiran.com/p1498858  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!