Application of Hybrid 6 degrees of freedom fixation could lead to space motion in each 3 anatomic plates together and decrease the time of complex deformities correction. This study is an investigation on the function of hybrid external fixation and the influence of it on decreasing the treatment time. About this case utilize of Ortho-SUV Frame (OSF) system is explained for the first time in Iran and report of its novel. These robotic systems are divided into two groups: active and passive, about active system all movements are done by actuators in joints and links. And in passive, the system needs an operator or patient to actuates Sturats by hand.
Methods
The femur bone has been investigated was non::union:: with deformity in sagittal, frontal and transversal planes. Ilizarov external fixation was applicate firstly, with this condition that the OSF systems jacks were replaced instead of simple rods in side of fracture. Software work was done on February of 2016 in Ayatollah Taleghani Hospital, Tehran, Iran. Fractures were happened in a car accident and some other operating were perforemed for this patient without any result.
Results
The correction of studied deformity needs 3 planar moving. Acting this movement by Ilizarov requirements 33 mm displacement in frontal plane, 12 mm horizontal distraction and 48 mm displacement in sagittal plane. Due to the rate of correction in Ilizarov which is 1 mm per day, this bone needs 93 days for general correction and three times changing in shape of rings connections. While, by using the hybrid external fixation, all displacements were corrected in 46 days and first connection had supported all planes.
Conclusion
According to that the decreasing of treatment time is one of the main goal, the hybrid external fixation systems could be an appointment choice in complex deformities and replaced with some common fixation. In addition to, using of updated software increases the accuracy of displacement.
Language:
Persian
Published:
Tehran University Medical Journal, Volume:75 Issue: 2, 2017
Pages:
120 to 125
magiran.com/p1707514  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!