به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت
فهرست مطالب نویسنده:

mahya hasanzadeh

  • Ali Mahmoud Hashemi, Mahya Hasanzadeh, Ameen Khraisat, Marzieh Alikhasi
    Objectives

    This study aimed to do a comprehensive systematic review on the comparison of digital and conventional workflows regarding prosthetic outcomes, accuracy of implant impressions, framework passivity and fit, and clinical fabrication of multi-unit implant-supported fixed restorations.

    Materials and Methods

    The EMBASE, PubMed, Scopus, and Cochrane Library databases were searched for relevant articles published up until April 2020.

    Results

    No in-vivo article was found to compare full digital and conventional workflows regarding the accuracy of implant impressions, passivity and fit of frameworks, and prosthetic outcomes. There was no study to investigate full digital and conventional workflows for clinical fabrication of multi-unit implant-supported fixed restorations.

    Conclusion

    This empty review highlights the need for further research to compare full digital and conventional workflows for implant-supported restorations.

    Keywords: Dental Prosthesis, Implant-Supported, Computer-Aided Design, Review
  • Ali Mahmoud Hashemi *, Mahya Hasanzadeh, Leila Payaminia, Marzieh Alikhasi

    Statement of the Problem: 

    Some components of implant treatment are reusable. Therefore, possible changes during fixation, removal, and sterilization process should be tested. Many studies have examined the reuse of implant parts, but the impact of repeated use of scan bodies on the accuracy of implant position has not been well investigated.

    Purpose

    The aim of this in vitro study was to compare the effect of repeated use of two different types of scan bodies on the accuracy of implant position.

    Materials and Method

    In this in vitro experimental study, two acrylic resin maxillary models, each with two implant analogues inserted at the site of missing first and second molars were used. Two types of scan bodies including titanium and polyetheretherketone (PEEK) were used for digital impression. Then they were ten times removed and autoclaved for sterilization. The first scan was considered as a reference to be compared with the other next nine scans. Values of linear distance between two scan bodies, diameter changes of each scan body, and three-dimensional linear displacement (ΔR) were measured. These values were compared between the two types of scan bodies using t-test (α=.05). 

    Results

    There was significant difference between titanium and PEEK scan bodies regarding inter-implant distance variation (p=.006) and diameter change (p< .001) in repeated use. However, for the ΔR, there was no significant difference between them (p= 0.759).

    Conclusion

    The results demonstrated that type of scan body could affect the accuracy of implant position transfer after repeated use. PEEK scan body performed better after 9 cycles of reuse in comparison with titanium scan body.

    Keywords: Computer aided design, Computer aided manufacturing, Dental Prosthesis, Implant supported, Impression technique
بدانید!
  • در این صفحه نام مورد نظر در اسامی نویسندگان مقالات جستجو می‌شود. ممکن است نتایج شامل مطالب نویسندگان هم نام و حتی در رشته‌های مختلف باشد.
  • همه مقالات ترجمه فارسی یا انگلیسی ندارند پس ممکن است مقالاتی باشند که نام نویسنده مورد نظر شما به صورت معادل فارسی یا انگلیسی آن درج شده باشد. در صفحه جستجوی پیشرفته می‌توانید همزمان نام فارسی و انگلیسی نویسنده را درج نمایید.
  • در صورتی که می‌خواهید جستجو را با شرایط متفاوت تکرار کنید به صفحه جستجوی پیشرفته مطالب نشریات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال