به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت
جستجوی مقالات مرتبط با کلیدواژه

data encoding

در نشریات گروه پزشکی
تکرار جستجوی کلیدواژه data encoding در مقالات مجلات علمی
  • Koel Datta Purkayastha ORCID, Chayan Nath, Sambhu Nath Pradhan
    Introduction

    This paper presents a portable device of Air Quality Monitoring System (AQMS) based on a sensor platform. The purpose of the study is to power awareness, warning indication, and minimal data storage capability.

    Materials and methods

    AQMS is developed by embedded design methodology. The software part is based on the C programming language. AQMS device is made up of “transmitter” and “receiver” sections through the Zigbee wireless network. The objective is to collect concentrations of CO, NO2, CO2, humidity, and temperature to check air pollution for health awareness. A power-saving strategy is adopted in the "transmitter" of AQMS through a Demultiplexer circuit. To minimize the space complexity of storage and availability of long-term data, data encoding techniques are implemented.

    Results

    By implementing switching activity on the sensors in AQMS, the active mode of sensing operations are controlled and a power saving of 18.41% is achieved. Extending the duration of transmission operation increases data storage in the “receiver” unit. Hence, two encoding techniques are developed where real-time data are encoded in binary form: 2-bit encoding and 3-bit encoding. According to the results, 2-bit encoding saves 50% of storage space and 3-bit encoding saves 25%, compared to not utilizing any encoding strategy, sacrificing data accuracy by less than 5%.

    Conclusion

    AQMS design is created with the implementations of low power consumption and low storage. Additionally, an alarming condition is set in AQMS for indicating the level of pollutants in the air to determine the risk level of exposure which is dangerous for human health.

    Keywords: Air pollution, Sensor, Wireless network, Low power, Data encoding
نکته
  • نتایج بر اساس تاریخ انتشار مرتب شده‌اند.
  • کلیدواژه مورد نظر شما تنها در فیلد کلیدواژگان مقالات جستجو شده‌است. به منظور حذف نتایج غیر مرتبط، جستجو تنها در مقالات مجلاتی انجام شده که با مجله ماخذ هم موضوع هستند.
  • در صورتی که می‌خواهید جستجو را در همه موضوعات و با شرایط دیگر تکرار کنید به صفحه جستجوی پیشرفته مجلات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال