  • Nahid Chegeni, Mohammad Javad Tahmasebi Birgani, Fariba Farhadi Birgani *, Daryoush Fatehi, Gholamreza Akbarizadeh, Marziyeh Tahmasbi
    Background

    Recently, magnetic resonance imaging (MRI)-based radiotherapy has become a favorite science field for treatment planning purposes. In this study, a simple algorithm was introduced to create synthetic computed tomography (sCT) of the head from MRI.

    Methods

    A simple atlas-based method was proposed to create sCT images based on the paired T1/T2-weighted MRI and bone/brain window CT. Dataset included 10 patients with glioblastoma multiforme and 10 patients with other brain tumors. To generate a sCT image, first each MR from dataset was registered to the target-MR, the resulting transformation was applied to the corresponding CT to create the set of deformed CTs. Then, deformed-CTs were fused to generate a single sCT image. The sCT images were compared with the real CT images using geometric measures (mean absolute error [MAE] and dice similarity coefficient of bone [DSCbone]) and Hounsfield unit gamma-index (THU) with criteria 100 HU/2 mm.

    Results

    The evaluations carried out by MAE, DSCbone, and THU showed a good agreement between the synthetic and real CT images. The results represented the range of 78-93 HU and 0.80-0.89 for MAE and DSCbone, respectively. The THU also showed that approximately 91%-93% of pixels fulfilled the criteria 100 HU/2 mm for brain tumors.

    Conclusion

    This method showed that MR sequence (T1w or T2w) should be selected depending on the type of tumor. In addition, the brain window synthetic CTs are in better agreement with real CT relative to bone window sCT images.

    Keywords: Deformable registration, Demons algorithm, radiotherapy, synthetic computed tomography