  • Fatemeh Javaherforooshzadeh *, MohammadReza Pipelzadeh, Reza Akhondzadeh, Sara Adarvishi, Mostafa Alghozat
    Background

    The benefit of sequential compression device (SCD) for the prevention of hypotension after spinal anesthesia in cesarean sections has not been determined.

    Objectives

    In this study, an attempt was made to determine whether SCD can prevent hemodynamic changes following spinal anesthesia for cesarean sections.

    Methods

    In a prospective clinical trial, 76 parturient women undergoing elective cesarean sections under spinal anesthesia were randomly divided into SCD or control groups. The maternal hemodynamic changes within 75 min after spinal anesthesia, nausea, vomiting, and neonatal Apgar score at 1 and 5 min were compared between the groups.

    Results

    There were no significant differences between the groups in the patients’ characteristics, maximum sensory block, skin incision to delivery time, spinal anesthesia to delivery time (min), and the total duration of surgery. Concerning heart rate changes, RM ANOVA showed a significant difference in the effect of time, groups, and the interaction of the two factors (P < 0.0001, P < 0.0001, and P < 0.0001, respectively). Tukey post hoc test showed that 3 min after spinal anesthesia, diastolic blood pressure was significantly higher in the SCD group than in the control group (P < 0.05). The SCD group had meaningfully lower rates of nausea (P = 0.005) and vomiting (P = 0.001) than the control group. The SCD group also demonstrated a significantly lower mean ephedrine dosage per patient (4.1 mg against 17.1 mg, P = 0.001). However, no significant difference was observed between the groups in terms of neonatal Apgar scores at 1 and 5 minutes.

    Conclusions

    This study showed that SCD could reduce extensive changes in diastolic blood pressure as an important hemodynamic parameter and the incidence of nausea and vomiting. Thus, SCD can be used in spinal anesthesia care practices for elective cesarean sections.

    Keywords: Cesarean Section, Spinal Anesthesia, Hemodynamic Changes, Sequential Compression Device