javad sadeh
-
Photovoltaic (PV) power plants include several parallel and series units. PV uncertainty due to scheduled or forced outages of these units affects the coordination of overcurrent relays (OCRs) and may violate the optimization constraint. This paper proposes a novel hybrid method to solve the selectivity problem of overcurrent relays due to photovoltaic power plant uncertainty. The proposed technique exploits K-medoids and interval linear programming (ILP) to provide setting groups (SGs). The recommended method not only maintains relay coordination for all PV generation scenarios, but also optimizes their operating time. In addition, this method can also be applied to the uncertainties caused by the synchronous distribution generation (DG) unit, which is verified in the studied networks. This research has been tested on the IEEE 8-bus and IEEE 30-bus distribution systems and the superiority of the proposed method in solving the selectivity problem and relay trip time optimization is demonstrated by the simulation results.Keywords: Overcurrent Relay, Setting Group, Photovoltaic, Uncertainty, K-Medoids, Interval Linear Programming
-
توسعه روز افزون خطوط چندپایانه فشار قوی جریان مستقیم (MTDC) به دلیل مزایای این نوع از شبکه نسبت به شبکه AC خصوصا در فواصل طولانی، توجه را بیش از پیش به ارائه راهکاری به منظور حفاظت و تخمین مکان خطا در این نوع شبکه جلب کرده است. در این مقاله روشی مبتنی بر معادلات حاکم بر خط برای مکان یابی خطا در یک شبکه MTDC ارائه شده است. در روش پیشنهادی فرض شده است ابزار اندازه گیری تنها بر روی پایانه های متصل به کانورتر نصب شده اند. الگوریتم پیشنهادی شامل سه بخش شناسایی قطب خطادار، تشخیص خط خطادار و تخمین مکان خطا است. برای شناسایی قطب خطادار، شاخص تغییرات ولتاژ پیشنهاد شده است. شناسایی قطب خطادار منجر به کاهش تعداد دفعات اجرای الگوریتم و سرعت بخشیدن به کل فرآیند تخمین مکان خطا می گردد. الگوریتم شناسایی خط خطادار نیز به دو زیر بخش برون خط و برخط تقسیم شده است. در بخش برون خط مفهومی تحت عنوان خطوط فرضی با توجه به ساختار شبکه معرفی می گردد که در یافتن مکان خطا تاثیر مثبتی دارد. در بخش برخط با استفاده از خطوط فرضی و تحلیل نتایج معادلات، روشی به منظور شناسایی خطوط سالم و در نتیجه تفکیک خط خطادار معرفی می شود. پس از شناسایی خط خطادار اگر اطلاعات حداقل یک سمت خط در دسترس نباشد، با استفاده از معادلات حاکم بر خط اطلاعات مورد نیاز تخمین زده می شود. به عنوان آخرین مرحله، مکان خطا نیز از میانگین نتایج حاصل از حل معادلات با استفاده از اطلاعات خط خطادار محاسبه می گردد. شبکه مورد مطالعه شامل خطوط هوایی و کابلی و ساختار شعاعی و حلقوی است تا صحت روش در تمامی حالات بررسی گردد. نتایج شبیه سازی های انجام شده، بیانگر عملکرد مناسب روش پیشنهادی به ازای خطاهای مختلف از جمله خطا در نزدیکی پایانه خطوط بلند و خطا با مقاومت بالا است.
کلید واژگان: خطوط چند پایانه جریان مستقیم، مکان یابی خطا ناحیه گسترده، مدل خط با پارامترهای گستردهJournal of Iranian Association of Electrical and Electronics Engineers, Volume:21 Issue: 2, 2024, PP 167 -183The increasing development of multi-terminal high-voltage direct current (MTDC) lines due to the advantages of this type of network over the AC network, especially in long distances, has drawn more attention to providing a solution to protect and estimate the fault location in this type of network. In this paper, a method based on distributed parameters line equations is presented for fault location in an MTDC network. In the proposed method, it is assumed that the measuring instruments are installed only on the terminals connected to the converter. The proposed algorithm includes three parts: identifying the faulty pole, detecting the faulty line and estimating the fault location. To identify the faulty pole, the voltage change index is proposed. Identifying the faulty pole leads to reducing the number of times the algorithm is executed and speeding up the entire process of estimating the fault location. Faulty line detection algorithm is also divided into offline and online subsections. In the offline section, a concept called hypothetical lines is introduced according to the network structure. In the online section, using hypothetical lines and applying line equations, a method is proposed to identify faulty lines. Then using a two-ended method, the location of fault is estimated in this line. If the data is not available on at least one side of the line, it is estimated using the distributed parameter line equations. The studied network includes overhead and cable lines and radial and ring structures so that the accuracy of the proposed method can be checked in all cases. The results of the simulations show the proper performance of the proposed method for various faults, including faults near the end of long lines and faults with high resistance.
Keywords: Multi-Terminal HVDC, Wide Area Fault Location, Distributed Parameters Line Model -
با توجه به مزایای فراوان بکارگیری واحدهای تولید پراکنده به ویژه آنهایی که از انرژیهای تجدیدپذیر و پاک استفاده مینمایند، اتصال آنها به شبکه توزیع به طور فزایندهای در حال گسترش است. در بین انواع مولدهای تجدیدپذیر، نیروگاه های فتوولتاییک به دلیل تولید انرژی پاک، بهره برداری و نگهداری ساده و دسترسپذیری در اکثر مناطق، بیشتر از سایر فن آوریها مورد توجه قرار گرفته اند. علیرغم مزایای اشاره شده، اتصال مولدهای فتوولتاییک به شبکه توزیع، مسایلی در زمینه حفاظت شبکه ایجاد خواهد کرد. امکان تداخل عملکرد رله ها و ناهماهنگی آنها، دوسوتغذیه شدن شبکه و وقوع حالت جزیرهای از جمله آنها هستند. از سوی دیگر، با افزایش نفوذ این مولدها، فعال بودن توابع پیشرفته حمایت شبکه از جمله تنظیمهای توان اکتیو و راکتیو، قابلیت گذر از افت ولتاژ (LVRT) و جابجایی بدون وقفه به حالت عملکرد مستقل به منظور جبران تولید غیرقابل پیش بینی آنها در دستورالعملهای کنونی شبکه (Grid Code) لحاظ شده است. از آنجاکه این خدمات جانبی میتواند عملکرد روش های آشکارسازی حالت جزیرهای را مختل نماید، ارایه روش آشکارسازی حالت جزیره ای با در نظر گرفتن خدمات جانبی، ضروری میباشد. در این مقاله برخی از روش های آشکارسازی حالت جزیرهای با قابلیت هماهنگی با توابع پیشرفته حمایت شبکه از جمله تنظیمهای توان، گذر از افت ولتاژ و جابه جایی بدون وقفه به حالت مستقل از شبکه مرور شده است.
کلید واژگان: مولد فتوولتاییک، آشکارسازی حالت جزیره ای، تنظیم توان، قابلیت گذر از افت ولتاژ، جابه جایی بدون وقفهAccording to wide variety of advantages of distributed generation units, especially those using clean and renewable energies, their installation are dramatically increasing in distribution networks. Among renewable energy generators, photovoltaic generation units have been paid more attention compared to other technologies because of clean energy generation, simple operation and maintenance, and availability in most areas. Despite the mentioned advantages, connecting the photovoltaic generation units to the distribution network will cause problems in the field of network protection. These include the possibility of overlapping relays and their non-coordination, bidirectional feeding network, and the occurrence of an islanding state. On the other hand, by increasing the penetration of these generators, the activation of advanced grid support functionalities such as active and reactive power regulations, low voltage ride through capability (LVRT) and seamless transition to islanded operation mode are included in current grid codes to compensate for their unpredictable energy production. Since these ancillary services can disrupt the operation of islanding detection methods, it is necessary to provide islanding detection method compatible with mentioned ancillary services. In this paper, islanding detection methods compatible with the advanced grid support functionalities such as power regulations, low voltage ride through, and seamless transition to islanded mode are reviewed.
Keywords: Photovoltaic generator, islanding detection, Power regulation, Low voltage ride through capability, Seamless transition -
در این مقاله روشی هوشمند با استفاده از شبکه عصبی و تبدیل موجک برای تشخیص جزیره ای شدن برای واحدهای تولید پراکنده مبتنی بر اینورتر ارائه شده است. روش ارائه شده مبتنی بر تغییر مرجع توان راکتیو در واسط کنترل اینورتر به منظور ایجاد یک گذرای اجباری کوچک در فرکانس و مشتق آن است. در شرایطی که واحد تولید پراکنده در جزیره قرار گرفته باشد، تغییر در مرجع توان راکتیو باعث تغییر در فرکانس سیستم و مشتق آن و ایجاد گذرایی در آنها خواهد شد. ایده اصلی این مقاله، استفاده از گذرای ایجاد شده در فرکانس و مشتق آن در شرایط جزیره ای شدن است. در این روش شبکه عصبی احتمالاتی (PNN) به وسیله شاخص استخراج شده از اطلاعات مشتق فرکانس، به وسیله تبدیل موجک گسسته (DWT) در شرایط جزیره و غیر جزیره تحت آموزش قرار می گیرد. شبیه سازی ها با استفاده از نرم افزار PSCAD/EMTDC و تحلیل ها در نرم افزار MATLAB انجام شده است. نتایج شبیه سازی ها نشان می دهد که روش پیشنهادی در شرایط مختلف عملکرد مناسبی از خود نشان می دهد.
کلید واژگان: واحدهای تولید پراکنده اینورتری، تشخیص جزیره ای شدن، تبدیل موجک، شبکه عصبی احتمالاتیIn this paper، an intelligent islanding detection method is presented for inverter based distributed generation (DG) using probabilistic neural network (PNN) and wavelet transform. The presented method is based on the change of DG reactive power reference (Qref) in inverter control interface to create a small forced transient in frequency and its derivative. Changing the Qref causes a forced transient in system frequency and also in its derivative in islanding conditions. The main idea is to use the created transient in frequency derivative in islanding conditions. The PNN is trained by features extracted from the frequency derivative data through the discrete wavelet transformation (DWT) in islanding and non-islanding conditions. The proposed method is evaluated in islanding and non-islanding conditions، using PSCAD/EMTDC and MATLAB software. Simulation results show that the proposed method has a proper operation in the islanding and non-islanding conditions.
Keywords: Inverter based DG, Islanding detection, wavelet transform, Probabilistic neural network -
در سیستم قدرت معمولا رله های دیستانس به عنوان حفاظت اصلی خطوط انتقال ولتاژ بالا به کار گرفته می شوند و عملکرد صحیح آنها به لحاظ سلامت اجزا و پایداری سیستم از اهمیت ویژه ای برخوردار است. نوسان توان یکی از پدیده هایی است که می تواند باعث عملکرد اشتباه و نابجای رله های دیستانس معمولی گردد و در حالی که خطایی در سیستم وجود ندارد، تداوم انتقال انرژی الکتریکی را به مخاطره بیاندازد. در این مقاله، روشی مبتنی بر طبقه بند و بر اساس ماشین بردار پشتیبان (SVM) جهت شناسایی نوسان توان از خطای اتصال کوتاه در رله های دیستانس دیجیتالی ارائه گردیده است. سپس از طریق شبیه سازی یک سیستم قدرت نمونه و پردازش سیگنال های ولتاژ و جریان، تعدادی الگو برای یادگیری و تست طبقه بند SVM تولید شده و از این طریق عملکرد روش پیشنهادی مورد آزمایش و بررسی قرار گرفته است. همچنین به کمک الگوهای تست و یادگیری تولیده شده، ساختار مناسبی برای طبقه بند مورد نظر انتخاب شده است. مجموعه الگوهای یادگیری و تست، ترکیبی از حالت های مختلف نوسان توان و انواع خطاهای متقارن و نامتقارن را شامل می شود. نتایج آزمایش های انجام شده بیانگر کارآمدی الگوریتم حفاظتی پیشنهادی می باشندکلید واژگان: خطوط انتقال، حفاظت دیستانس، نوسان توان، خطای اتصال کوتاه، ماشین بردار پشتیبان (SVM)In power systems، distance relays are utilized widely as main protection of the high voltage transmission lines، and their safe operation has significant effects on health of the components and stability of the system. Power swing is a phenomenon that can cause mal-operation of the distance relays while there is no fault in the system. In this paper، a protection scheme based on Support Vector Machine (SVM) classifier is proposed for the digital distance relays to distinguish between power swings and faults. In this work، simulations are done on a study system and related train and test patterns are generated to analyze performance of the proposed method. Also، the proper structure of the SVM classifier is investigated using the train and test patterns. The train and test patterns contain information of the different power swing conditions and symmetrical and asymmetrical types of faults. The results of the tests and simulations confirm the efficiency of the proposed protection algorithm.Keywords: Transmission Lines, Distance Protection, Power Swing, Short Circuit Fault, Support Vector Machine (SVM)
-
بررسی نحوه عملکرد پست های فشار قوی DCS و ارزیابی اقتصادی استفاده از این نوع پست ها در شبکه برق ایرانمقوله ارتباطات در پست های فشار قوی در طی سالهای اخیر دستخوش تغییرات زیادی بوده است. سیستم های اتوماسیون پست های فشار قوی اطلاعات موجود در سطوح مختلف پست را به صورت دیجیتال و از طریق پروتکل های مختلفی به سطوح بالا دست منتقل می کنند. استفاده از این سیستم ها، عملیات کنترل و مانیتورینگ درشبکه را بطور چشمگیری بهبود می بخشد. از سوی دیگر استفاده از سیستم های اتوماسیون پست مستلزم صرف هزینه راه اندازی بیشتری در مقایسه باپست های با سیستم کنترل معمولی می باشد. در این مقاله سعی شده است تا بررسی جامعی در رابطه با جایگزینی این نوع پست های اتوماسیون یافته تحت عنوان پست های DCS به جای پست های نسل قدیم از لحاظ نحوه عملکرد ونیزصرفه اقتصادی انجام شود.
کلید واژگان: ادوات الکتریکی هوشمند(Intelligent Electronic Device، IED)، پست های فشار قوی DCS - سطوح پروسس، بی، ایستگاهStudy method of operation high voltage power substation DCS & Economic appraisal using of this substation in power system iranCommunication approaches in high voltage power substations have been on great evolution in recent years. automation systems in high voltage substations transfer digital data via different protocols to upper-hand levels. using these systems make control and monitoring systems work much more effective. In other hand using substation automation systems needs investing more amount of money in comparison with substations with conventional control and protection subsystems. this paper includes a quiet complete analysis on substituting this sort of high voltage substation called 'DCS substitutions 'with conventional ones, both from technical and economical points of viewKeywords: Intelligent Electronic Device, IED