Exploring the Reasons for Orthopedic Implant Failure in Traumatic Fractures of the Lower Limb

Message:
Abstract:
Background
A damaged orthopedic implant in the body can cause problems for the patient and disrupt the therapeutic process. This study investigates various factors for orthopedic implant failures in patients with traumatic lower limb fractures who referred to a trauma center in Mashhad, Iran.
Methods
This was a prospective study of 23 patients referred to Kamyab University Hospital with failed orthopedic implants in 2009. We included any patient with an orthopedic device previously implanted secondary to a traumatic lower limb fracture who later presented to Kamyab University Hospital because of a failed implant.For all patients, a thorough history was taken and the necessary investigations that included radiographic studies were performed. We investigated the quality of the failed devices by chemical analysis, metal hardness testing and metallography. The results were statistically analyzed.
Results
The mean age of the patients was 33 ± 19 years. There were 19 (82.5%) male and 4 (17.4%) female patients. In 14 (60.9%) cases, there were failed femoral implants and 9 (39.1%) cases had failed implants for tibial fractures. We compared the implants against ASTM standards. According to chemical analysis, all internally produced devices and one of the leading international brands were within the expected standard. However, in 3 cases chemical analysis showed a deviation from the standards. These were manufactured by “miscellaneous” companies. In one (4.3%) case the device failure was iatrogenic, in 14 (60.9%) it was due to faulty implants and in 8 (34.8%) cases, the patients were non-compliant with instructions. Hardness testing was satisfactory in all cases and metallographic studies showed good quality for the leading international brands, satisfactory quality for the internally produced devices and poor quality for the miscellaneous devices.
Conclusion
The implants classified as miscellaneous were of poor quality. Thus, we cannot recommend their use in orthopedic surgeries. We recommend using credible, known brands.
Language:
English
Published:
Archives of Iranian Medicine, Volume:16 Issue: 8, Aug 2013
Page:
478
magiran.com/p1158762  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!