Scanning Electron Microscope (SEM) Evaluation of Composite Surface Irradiated by Different Powers of Er:YAG Laser
Author(s):
Abstract:
Introduction
The aim of this study was to evaluate the composite surface treated by different powers of Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser in comparison with bur preparation via scanning electron microscope.Methods
Fourteen composite resin blocks with 15× 10 × 10 mm dimensions were used in this study. The samples were divided to seven groups as follow: Group 1 (power: 1 W, Energy: 50 mJ); Group 2 (power: 2 W, Energy: 100 mJ); Group 3 (power: 3W, Energy: 150 mJ); Group 4 (power: 4 W, Energy: 200 mJ); Group 5 (power: 5W, Energy: 250 mJ); Group 6 (power: 6 W, Energy: 300 mJ); Group 7: Diamond bur. Then, the samples were prepared for SEM examination.Results
The surface treated by Er:YAG laser showed irregular and micro porous surface.Conclusion
It seems that composite surface treatment by Er:YAG laser can be an alternative method for composite repair if suitable parameters are used.Keywords:
Er , YAG laser , composite resin , SEM
Language:
English
Published:
Journal of Lasers in Medical Sciences, Volume:6 Issue: 2, Spring 2015
Pages:
80 to 84
https://www.magiran.com/p1390028