Highly Sensitive FRET-Based Fluorescence Immunoassay for Detecting of Aflatoxin B1 Using Magnetic/Silica Core-Shell as a Signal Intensifier
Author(s):
Abstract:
Background
Recently, some new nanobiosensors using different nanoparticles or microarray systems for detection of mycotoxins have been designed. However, rapid, sensitive and early detection of aflatoxicosis would be very helpful to distinguish high-risk persons.Objectives
We report a highly sensitive competitive immunoassay using magnetic/silica core shell as a signal intensifier for the determination of aflatoxin B1 using fluorescence resonance energy transfer (FRET) from Cd/Te quantum dots (anti-aflatoxin B1 antibody immobilized on the surface of Cd/Te quantum dots) to Rhodamine 123 (Rho 123-labeled aflatoxin B1 bound to albumin). The specific immune-reaction between the anti-aflatoxin B1 antibody on the QDs and the labeled-aflatoxin B1 brings the Rho 123 fluorophore (acting as the acceptor) and the QDs (acting as the donor) in close spatial proximity and causes FRET to occur upon photo-excitation of the QDs. Using magnetic/silica core shell to intensify the obtained signal is the novelty of this study.Materials And Methods
Cd/Te QDs were synthesized by the simultaneous reduction of cadmium chloride and tellurium in the presence of sodium borohydride under nitrogen atmosphere. Magnetic nanoparticles were synthesized using FeSO4 and FeCl3 (1:2 molar ratio) and ammonia as an oxidizing agent under nitrogen atmosphere. The prepared magnetic nanoparticles shelled by silica using tetraethoxysilane in the presence of ammonia. Nanoparticles synthesis and monodispersity confirmed by TEM. Immobilization of Cd/Te QDs to antibodies and labeling of aflatoxin B1-albumin by Rho 123 were performed by EDC/NHS reaction in reaction mixture buffer, pH 6, at room temperature.Results
By using the magnetic/silica core shell sensitivity of the system changed from 2×10-11 in our previous study to 2×10-12 in this work. The feasibility of the method established by the detection of aflatoxin B1 in spiked human serum. There is a linear relationship between the decreased fluorescence intensity of Rho 123 with increasing concentration of aflatoxin B1 in spiked samples, over the range of 0.01-0.06 mmol.mL-1. Conclusion
This homogeneous competitive detection scheme is simple, rapid and efficient, and does not require multiple separation steps and excessive washing.Keywords:
Language:
English
Published:
Iranian Journal of Biotechnology, Volume:13 Issue: 3, Summer 2015
Pages:
25 to 31
https://www.magiran.com/p1465999
سامانه نویسندگان
مقالات دیگری از این نویسنده (گان)
-
The In vitro Effect of Nanoliposomal Amphotericin B Against Rhizopus arrhizus Isolated From COVID-19-Associated Mucormycosis Patients
Ali Ahmadi, Sayed Jamal Hashemi, Seyed Mahdi Rezayat, Roshanak Daei Ghazvini, Mahmoud Reza Jaafari, Jamileh Esmaeili, Fatemeh Saiedmohammadi, Farzaneh Afshari, Laura Alcazar-Fuoli, Alireza Abdollahi, Sadegh Khodavaisy *
Iranian Journal Of Pathology, Winter 2025 -
Evaluation of the various fungal infection of the skin and gills using pathology, culturing, and molecular fungal DNA sequencing of the freshwater ornamental fish
Mahdi Ebrahimijafari, Mansour Bayat*, Adel Haghighi Khiabanian Asl, Hazaveh
Journal of Ornamental Aquatics,