Introduction
Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by guidelines. If the validity of 99mTc-DMSA scan for renal size assessment would be established and reported in routine clinical practice, it might be more helpful for diagnostic purposes obviating further modality use in kidney diameter assessment.
Methods
70 patients (25 males and 45 females) with the age range of 1 month to 78 years old (Mean ± SD = 18.1 ± 19.3) were included in the study. The longest axis diameter of each kidney was calculated by ultra sonography and planar 99mTc-DMSA scintigraphy. The difference in renal size estimation between US and different projections of 99mTc-DMSA scan was assessed using generalized linear model repeated measurement, pair wise comparison in Post Hoc and Bland-Altman analysis.
Results
16 (22.9%) reports were interpreted as normal study, while 54 patients had abnormality at least in one kidney. No significant difference was noticed between the kidney diameters in US as compared to the all views of 99mTc-DMSA scan. Only in the estimation of left kidney size using 99mTc-DMSA scan, there was significant difference between anterior and posterior oblique views as well as between lateral and posterior oblique views. Mean value of the differences (estimated bias) doesnt differ significantly from 0 on the basis of 1-sample t-test.
Conclusion
99mTc-DMSA scintigraphy is an accurate method for renal length measurement with excellent agreement with ultra sonography. Kidney length can be easily measured as a routine processing procedure of a 99mTc-DMSA scan and not only used for more accurate interpretation of the images but also added to the final report as valuable incremental information.
Language:
English
Published:
Iranian Journal of Nuclear Medicine, Volume:24 Issue: 1, Winter-Spring 2016
Pages:
23 to 28
magiran.com/p1493302  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!