The Chemical Clogging and its Effects on Hydraulic Performance of Different Types of Emitters with Different Flow Rates using Water of Karoun River

Abstract:
In order to study the chemical clogging and its effect on hydraulic performance of trickle irrigation system, four treatments includes compensating emitters (Netafim and Micro-Flapper), non-compensating emitters (Mehr and Goldani), three treatment of flow rates that includes 8, 4 and 2 lph (liters per hour) were selected and tested using Karoun river’s water in No. 1 research farm of Shahid Chamran University of Ahvaz. The experiment was conducted in a Completely Randomized Block Design (CRBD) and irrigation was performed in 31 times with irrigation frequency for two days, at pressure of 1.5 bar. The results showed that decreasing of flow rate of Micro-Flapper emitter with 8 and 4 LPH flows is higher than the other treatments and this decreasing is significante at the five percent. Also the Micro-Flapper emitter with 2 lph flows has the lowest decreasing of flow rate. Based on field observations, herniation of silicon diaphragm that used in Micro-Flapper emitters with 8 and 4 lph flows is the main reason for the reduction of flow rate and high values of CV, qvar and qd. So in this particular case the Chemical sediment did not impose a major effect. Turbulent regime of water at the outlet is the reason of resistance against the chemical clogging in the Micro-Flapper emitter with 2 lph flows. In Netafim emitter with 8 and 4 lph, despite having the significant clogging in five percent signification level have a minimal values of CV, qvar and qd and high values of EU and CU. In this experiments, the treatment which had the lowest coefficient of manufacturing Variation, was accounted to it the lowest coefficient of variation of flow rate and the highest Emission Uniformity of variation. In most treatments during the Irrigation, values of CV, qvar and qd increased and values of EU and CU decreased. According to the results presented, the Goldani emitter with 8 gph flows is rated and selected as the top emitter in both terms of resistance against the chemical clogging and hydraulic performance parameters than other emitters.
Language:
Persian
Published:
Irrigation Sciences and Engineering, Volume:38 Issue: 3, 2015
Pages:
73 to 87
magiran.com/p1536685  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!