Advanced Virtual Monochromatic Images from Dual Source Dual-Energy CT for a Reduction in the Contrast Medium Dose (389 mgI/kg) in Multiphase Liver CT: Evaluation of Image Quality and Focal Lesion Conspicuity

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:

 

Background

Low-energy advanced virtual monochromatic images (VMIs) from dual source dual-energy CT (DSCT) could be applied to reduce contrast medium dose due to superior iodine contrast-to-noise ratios (CNRs).

Objectives

To investigate feasibility of advanced VMIs from DSCT to reduce contrast medium dose in multiphase liver CT without impairing image quality and conspicuity of focal hepatic lesions (FHLs).
Patients and

Methods

Ninety-four patients with 110 FHLs underwent follow-up CT twice prospectively with different protocols: protocol A, conventional 100 kVp and 555 mgI/kg; protocol B, dual-energy mode and 389 mgI/kg. The signal-to-noise ratio (SNR) and lesion-to-liver CNR were compared between the VMIs (40 - 120 keV, 10-keV interval) reconstructed using advanced image-based algorithm and conventional images. Two radiologists qualitatively evaluated VMIs, compared with the 100 kVp images, using a six-point scale.

Results

The SNRs of pancreas, aorta, portal and hepatic vein were similar to those at 100 kVp images (P > 0.05) at 40-50 keV images during late arterial phase (LAP) and at 40-60 keV images during portal venous phase (PVP) except for the SNRs of aorta and veins at 40 keV images which were significantly higher (P < 0.0109) during both phases and PVP, respectively. The CNR of 56 hypervascular FHLs was significantly higher at 40 - 50 keV images (P < 0.0002) and was similar at 60 keV images (P > 0.05) during LAP. The CNR of 58 hypovascular FHLs was similar at 40 - 120 keV images (P > 0.05) during PVP. Among the VMIs, 50 keV and 50 - 60 keV images received the highest scores (P < 0.0315 and P < 0.0041) by both reviewers during LAP and PVP, respectively.

Conclusion

Advanced 50 - 60 keV images from DSCT allowed contrast dose reduction by 30% in multiphase liver CT without impairing image quality and conspicuity of FHLs, compared with the conventional 100 kVp images with 555 mgI/kg.

Language:
English
Published:
Iranian Journal of Radiology, Volume:16 Issue: 3, Jul 2019
Page:
5
magiran.com/p2007818  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!