Progressive Collapse Analysis Of Flat Slab Buildings With Post-Punching Effect

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:

The reinforced concrete flat slab is one of the types of floor systems used to construct residential, office and parking buildings. Because of the direct transfer of floor loads to columns, flat slabs are susceptible to punching failure in slab-column connections. The punching failure in one column can initiate failure in adjacent columns and cause progressive punching shear failures resulting in the progressive collapse of the entire structure. Using the post-punching capacity of the connections can prevent or minimize the likelihood of such failures. The post-punching resistance of slab-column connections in the absence of shear reinforcements is provided by the dowel action and vertical component in flexural and integrity bars when they deflect after punching. Most studies of flat plate performance were attended to punching shear failure and the post-punching behaviour of flat slabs is ignored. This can reduce accuracy in progressive collapse analysis.This paper validates analytical methods previously proposed by the authors to simulate post-punching behaviour a multi-panel flat plate system. Then, the progressive collapse potential of a three-story flat slab building was evaluated using the proposed analytical model. The effect of factors such as column removal position, structural member damage due to previous seismic loads on subsequent failures, floor load intensity, and boundary conditions (slab expansion around the building) on flat slab structural behaviour were investigated. The analysis results showed that the building internal column removal would cause the punching failure in the adjacent slab-column connections, but due to the post-punching resistance of the connections, overall failure did not occur. Therefore, ignoring the effect of post-punching resistance on slab-column connections can lead to an error in the evaluation of the progressive failure potential of flat slab structures. The analysis results revealed that the internal column removal of the building is the most critical. In the structure, with the slab expansion around the building, the removal of the edge column is the most critical scenario. The Dynamic Amplification Factor (DAF) was calculated by comparing static and dynamic vertical displacements for model structures. The analysis results showed that DAF could be greater than 2 in the flat plate slabs.

Language:
Persian
Published:
Sharif Journal Civil Engineering, Volume:37 Issue: 1, 2021
Pages:
131 to 141
magiran.com/p2334578  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!