Background & Objects

 According to sixth issue of the National Building Regulations in Iran, the calculation of building structures against lateral forces of wind and earthquake is done separately. Maximum effect of these two lateral forces is used to calculating criterion of each element of the structure. In any case, it is mandatory to observe the special rules of seismic design according to the structural system in all members. Since most parts of the country are located on the plateau of Iran, which is at a high level in terms of seismicity, many engineers pay special attention to the seimic loads, versus wind loads.

Method

In this study, while reviewing the wind phenomenon, within the framework of the methods approved by the regulations and applicable standards of the country, all possible situations and design criteria in the lateral wind force calculating in different buildings of the country have been analyzed by comparing the earthquake lateral force. Among the studied areas, the results of provincial centers are presented in this article. The impact of all types of soil, structural systems, seismic hazard zone, the importance of buildings according to the building function and existing standards of the country is considered in this study. More over, according to the different building function and structural system, the necessary gravitational loads have been applied in the calculation process.

Findings

The elevation level of dominance of static wind load versus equivalent static earthquake load is obtained in studied areas and considering the allowable height of the structural systems. According to the rules; the lateral wind load from this level upwards should be the main criterion for the design of building structures. The results in the form of different tables indicate the height levels that the design needs to be considered more seriously against lateral wind force.

Conclusion

The results of the analysis indicate that by increasing the values ​​of the behavior factor of buildings, the height level of the structure when the lateral force of the wind overcomes the lateral force of the earthquake decreases. Ardabil, Zahedan and Kerman are among the critical areas against wind due to the regional wind speed of 130 km per hour, which requires more attention of structural engineers. Alborz, Ilam, Kohkiluyeh and Boyer-Ahmad provinces have less sensitivity in terms of wind lateral load because they have an average wind speed of less than 80 km per hour in all seasons. The wind lateral force in the initial levels of altitude is dominant over the seismic lateral force for all types of structural systems with different importance in most sites with soil type I. Therefore, it needs special attention.

Language:
Persian
Published:
Journal of Disaster Prevention and Management Knowledge, Volume:11 Issue: 4, 2021
Pages:
348 to 365
magiran.com/p2352831  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!