Calculation of magnetic field effects on dose distribution, inside a heterogeneous phantom, in MR-guided helium ion-therapy using FLUKA Monte Carlo simulation code
Author(s):
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
In this work, the impact of magnetic field presence on the central axis depth-dose curves of helium ion beams inside a heterogeneous phantom with air and bone layers was investigated. According to the calculations, presence of the magnetic field has a considerable impact on the dose distribution of helium beams depending on the field strength and beam energy. A 32.3% abrupt increase and 92.5% reduction in dose were observed at the boundary between the water-air and the water-bone layer insert, respectively. The accuracy of the simulation was evaluated by verifying the depth dose curves of helium ion beams in a water phantom with experimental data.
Keywords:
Language:
English
Published:
Radiation Physics and Engineering, Volume:3 Issue: 1, Winter 2022
Pages:
39 to 42
https://www.magiran.com/p2420842