Differences and Limits of Agreement among Pentacam, Corvis‑ST, and IOL‑Master 700 Optical Biometric Devices regarding Central Corneal Thickness Measurements

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Purpose

To investigate the differences and limits of agreement in measuring corneal thickness using Pentacam, Corvis, and intraocular lens (IOL)‑Master 700 devices.

Methods

This study was conducted on 37 right eyes of 21 males and 16 females (n = 37) with a mean age of 52.11 ± 6.30 years. The central corneal thickness was measured using three optical biometric devices, including Pentacam, Corvis, and IOL‑Master 700. The inclusion criteria were normal eyes without any ophthalmological abnormalities, history of ocular pathology, or ocular surgery. The data obtained from these three devices were compared two by two. The correlation and agreement limits among them were analyzed using statistical techniques.

Results

The mean standard deviation differences between Pentacam and Corvis, Pentacam and IOL‑Master 700, as well as Corvis and IOL‑Master 700 regarding the corneal thickness measurement, were 22.13 ± 8.05, 7.91 ± 8.02, and 14.21 ± 9.85 μm, respectively, which were statistically significant (P < 0.0001). Based on the investigation of the limits of agreement according to the Bland Altman method, the corresponding values between Pentacam and Corvis, Pentacam and IOL‑Master 700, and Corvis and IOL‑Master 700 were ‑16.2 to +15.4, ‑15.8 to +16.3, and ‑20.1 to +20.0 μm, respectively. Furthermore, the correlation coefficients of the measurements obtained by Pentacam and Corvis, Pentacam and IOL‑Master 700, as well as Corvis and IOL‑Master 700 were determined 0.957, 0.964, and 0.948, respectively (P < 0.0001).

Conclusion

The results from this study indicate that the interchangeable use of these three devices is not appropriate due to statistically significant differences and broad limits of agreement among the three devices, especially between Corvis and IOL‑Master 700.

Language:
English
Published:
Journal of Current Ophthalmology, Volume:34 Issue: 1, Jan-Mar 2022
Pages:
44 to 49
https://www.magiran.com/p2421793  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با ثبت ایمیلتان و پرداخت حق اشتراک سالانه به مبلغ 1,390,000ريال، بلافاصله متن این مقاله را دریافت کنید.اعتبار دانلود 70 مقاله نیز در حساب کاربری شما لحاظ خواهد شد.

پرداخت حق اشتراک به معنای پذیرش "شرایط خدمات" پایگاه مگیران از سوی شماست.

اگر مقاله ای از شما در مگیران نمایه شده، برای استفاده از اعتبار اهدایی سامانه نویسندگان با ایمیل منتشرشده ثبت نام کنید. ثبت نام

اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!