Investigation the Efficacy of Fuzzy Logic Implementation at Image‑Guided Radiotherapy

Message:
Article Type:
Short Communication/Paper (دارای رتبه معتبر)
Abstract:

At image‑guided radiotherapy, technique, different imaging, and monitoring systems are utilized for (i) organs border detection and tumor delineation during the treatment planning process and (ii) patient setup and tumor localization at pretreatment step and (iii) real‑time tumor motion tracking for dynamic thorax tumors during the treatment. In this study, the effect of fuzzy logic is quantitatively investigated at different steps of image‑guided radiotherapy. Fuzzy logic‑based models and algorithms have been implemented at three steps, and the obtained results are compared with commonly available strategies. Required data are (i) real patients treated with Synchrony Cyberknife system at Georgetown University Hospital for real‑time tumor motion prediction, (ii) computed tomography images taken from real patients for geometrical setup, and also (iii) tomography images of an anthropomorphic phantom for tumor delineation process. In real‑time tumor tracking, the targeting error averages of the fuzzy correlation model in comparison with the Cyberknife modeler are 4.57 mm and 8.97 mm, respectively, for a given patient that shows remarkable error reduction. In the case of patient geometrical setup, the fuzzy logic‑based algorithm has better influence in comparing with the artificial neural network, while the setup error averages is reduced from 1.47 to 0.4432 mm using the fuzzy logic‑based method, for a given patient.Finally, the obtained results show that the fuzzy logic based image processing algorithm exhibits much better performance for edge detection compared to four conventional operators. This study is an effort to show that fuzzy logic based algorithms are also highly applicable at image‑guided radiotherapy as one of the important treatment modalities for tumor delineation, patient setup error reduction, and intrafractional motion error compensation due to their inherent properties.

Language:
English
Published:
Journal of Medical Signals and Sensors, Volume:12 Issue: 2, Apr-Jun 2022
Pages:
163 to 170
magiran.com/p2430676  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!